Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM00027
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. General: The Site Plan indicates the north wall of the new building is 6' from the property line. Per the IBC Table602, the fire resistance rating for that wall in one hour. Please indicate this on the drawings, and provide a U.L. Listing Number for that required rating, or indicate the Item Number for that wall per the IBC Tables 721.1(1) and 721.1(2). 2. General: The Site Plan indicates the south wall of the new building is 11'-4" from the north wall of the existing building. Please indicate on the drawings the requirements of the IBC Section 705.3 (Exception 1) are met for the allowable building area in the IBC Table 506.2. 3. General: Please provide a Code Analysis on the drawings indicating the Occupancy Classification of the new building (IBC Chapter 3), the Construction Type of the new building (IBC Chapter 6), the Occupant Load of the new building (IBC Table 1004.5), Allowable Building Height (IBC Table 504.3), Allowable Building Area (IBC Table 506.2), and if the new building has an Automatic Sprinkler System. 4. General: Drawings 1, 2, and 3 are not clear when enlarged for review purposes (includes professional seal, signature, and date). 5. General: Please provide written responses to all review comments. |
| 01/19/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 01/19/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 01/19/2022 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 01/25/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 01/25/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Please provide a Code Analysis on the drawings indicating the Occupancy Classification of the new building (IBC Chapter 3), the Construction Type of the new building (IBC Chapter 6), the Occupant Load of the new building (IBC Table 1004.5), Allowable Building Height (IBC Table 504.3), Allowable Building Area (IBC Table 506.2), and if the new building has an Automatic Sprinkler System. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 01/26/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM00027 770 W Grant Rd – C-2 New Metal Building (1st Review) TRANSMITTAL DATE: January 26, 2022 This site is located in the C-2 zone (UDC 4.7.21). A Automotive Major Service and Repair (excluding bodywork and paint-booths) is a permitted use in this zone (Table 4.8-4) subject to Use Specific Standard 4.9.13.E 1. UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966 |
| 01/26/2022 | SSHIELD1 | ENGINEERING | REVIEW | Reqs Change | See Zoning comments |
| 01/26/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed |