Permit Number: T22BU00335
Parcel: 110073730

Review Status: Completed

Review Details: WALLS - SUBMITTAL

Permit Number - T22BU00335
Review Name: WALLS - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2022 GPENNIN1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Georgia Pennington
Planner

PROJECT: T22BU00335
4266 E Los Robles St
(Fence) (1st Review)

TRANSMITTAL DATE: (8/24/22)

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

1. Provide a residential plot plan that includes everything on this template: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

2. Label all structures on the plot plan. It appears there is a structure in the southern portion of the plot plan. Please provide permit documentation for this.

3. Provide the height or elevations (with height shown) of the proposed fence
.

If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov.
08/29/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide the fence height
09/01/2022 AWARNER1 NPPO REVIEW Approved
09/12/2022 SHASEMA1 ENGINEERING REVIEW Reqs Change Project: T22BU00335

Address: 4266 E LOS ROBLES ST

This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)

Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.

Instructions:

1. Is this for a new or existing activity application? – Please select New Application.

2. Submission Type – Select Floodplain Use Permit.

3. Project Name – Enter a name for your project.

4. Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.)

5. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided.

6. Description of Work – Enter in Floodplain Use Permit for…and then put a description of the work being done or reference the building permit number associated with this floodplain use permit.

7. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account.

8. Complete the Contractor, Owner and Architect/Engineer sections as applicable.

9. Supporting Documentation Upload – Provide a complete cost estimate for the project unless it is for a new build/separate structure. You may also provide additional documents you think will be helpful.

10. Sign the application and submit.

Contact Scott Haseman at scott.haseman@tucsonaz.gov, Stephen Blood at Stephen.Blood@tucsonaz.gov, or Loren Makus at Loren.Makus@tucsonaz.gov if you have any questions about the FUP.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/12/2022 NGARCIA3 OUT TO CUSTOMER Completed