Permit Number: T22BU00310
Parcel: 116277190

Review Status: Completed

Review Details: POOL - SPA

Permit Number - T22BU00310
Review Name: POOL - SPA
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 International Swimming Pool and Spa Code and 2018 International Residential Code with amendments on 1/1/2019 along with requirements of the Arizona Revised Statute 36-1681. Show the current code reference on the plans.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration

SITE PLAN:

1. Show compliance with the pool enclosure barrier requirement by including a continuous 5 foot barrier around the pool, ARS 36-1681.
2. Show compliance with the pool barrier from a dwelling by including a UL 2017 listed pool alarm system for doors and windows open to the pool, or show a continuous barrier around the pool, 2018 ISPSC 305.4.1.

STRUCTURAL PLANS:

1. Show the length of retainer wall and show any wall or fence on top, R301.1.3.

ELECTRICAL PLANS:

1. Bond the perimeter surface and reinforcing steel as required by ISPSC 302.1 and NEC680.26(B)(2).

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/23/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review Section


PROJECT:
T22BU00310
300 S Corte Tortuga Vista – SR
Swimming Pool (1st Review)


TRANSMITTAL: August 23, 2022
This site is located in the SR zone (UDC 4.7.4). A single-family residence (SFR) with pool is a permitted use in this zone (Table 4.8-1).

1. Show the 25’ slope easement that runs along the east property line, as shown on the final plat, Sierra Tortuga Lots 1-14, on the plan. Additional comments may be forth coming.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/23/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change 1. According to the Tentative Plat for Sierra Tortuga and the original Site-Grading Plan for Lot 10 (T08BU01787), there is no more new gradable area left from the alotted amount of disturbed area from the tentative plat.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
08/24/2022 NGARCIA3 OUT TO CUSTOMER Completed