| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 05/13/2022 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | Below are comments on the authorized repair submittal for COT ID# 408 at 1 East Prince Road (T22BU00174) Sheet 1 of 2 1. In Billboard Note #6, the valuation appears to be excessive for this type of work; revise as necessary. 2. After Billboard Note #7, insert as Billboard Note #8 the longstanding standard language regarding billboards listed on Exhibit 5 of the Stipulation: “All billboards enumerated in Exhibit 5 of the Stipulation shall provide a note providing the end date of the modification period. This sign is not listed in Exhibit 5.” [renumber following paragraphs to conform] 3 In Billboard Note #8 (renumbered to #9), revise to reflect the longstanding standard language: “The billboard shall not be relocated, changed in height, and face size shall not be increased or altered. 4. In Billboard Notes, delete Billboard Notes #9 and #10 (numbers as submitted), and replace with Billboard Note #10 as follows: “The billboard has no light fixtures or other electrical parts and no light fixtures or other electrical parts are to be added.”. 5. In aerial photograph underlay site plan, there are numerous errors and omissions regarding property line dimensions and dimensions setting the location of the billboard footprint; correct the north property line, as the stated 67 feet exceeds the actual by some 16 feet; correct the east property line, as the 176’ shown does not match the plat or adjacent survey, add the omitted south property line dimension, revise 126.25 feet shown for the partial west property line that is dated and does not correspond to any current line; and add other omitted dimensions; as to dimensions related to the billboard footprint, the sums of the dimensions need to match that for the adjacent property lines; all dimensions should be called out to at least one decimal place; and further note that while the standard for placement of the billboard footprint is within a tolerance of +/- 3 feet, the sums of the dimensions for the footprint relative to property lines need to be accurate. Sheet 2 of 2 1. In 3rd paragraph of boxed notes in the uppermost right area of the plan sheet, add “U” to reflect replacement of the bolts and nuts attaching stringers to uprights. 2. In 1st paragraph of Scope of Work, correct or otherwise explain why only one vertical trim piece is listed (compared to two in the 4th paragraph) 3. In 3rd paragraph of Scope of Work, correct an apparent typographical error by adding “x” to the stringer dimensions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/13/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |