| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2022 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 06/06/2022 | GLENN MOYER | ADMINISTRATIVE | ADMIN REVIEW | Denied | Below are comments on the authorized repair submittal for COT ID# 197 at 4550 South 6th Avenue (T22BU0140). Sheet 1 of 2 1. In aerial photograph underlay site plan, add the dimensions for each of the five property lines for the subject site, called out to at least one decimal place. 2. In aerial photograph underlay site plan, add the dimensions for the length and width of the billboard footprint, called out to at least one decimal place. 3. In aerial photograph underlay site plan, assure that the sum of the north-south & east-west dimensions to, from, and including the billboard footprint matches the applicable property line dimensions for this rectalinear property (note that the established standard of +/- 3’ for the location of the billboard footprint, but once that location is set the associated locational dimensions need to be accurate). 4. Clean up the duplications of the street names, particularly for Illinois street where the two names overlap. 5. Add PDSD activity number obtained since original submittal to plan sheet. Sheet 2 of 2 1. In 5th paragraph of Scope of Work, add standard reference “(like)” to plywood MDO trim. 2. Add standard multi-view detail on the plan sheet for the panel clips to be removed. 3. In South Sign Face Elevation, the 34’0” height specified exceeds actual height by more than one foot; revise to accurate height. 4. In South Sign Face Elevation, revise reference to existing face from “to remain” to “to be removed and reinstalled”. 5. In Poster Panel Top View, revise reference to existing face from “to remain” to “to be removed and reinstalled”. 6. In Poster Panel Side View, revise two references to wood trim by adding standard “(like)” to the references. 7. In Detail “A” of Poster Panel Side View, revise two references to wood trim by adding standard “(like)” to the references. 8. Add PDSD activity number obtained since original submittal to plan sheet. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/06/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |