| 03/08/2022 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 03/17/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show compliance with the gate swing away from water and a UL 2017 pool alarm system for doors and windows open to the pool, 2018 ISPSC 305.4.1. Update 12" conductor depth notation in conpliance with 2018 IRC Table E3803.1. Nonmetallic raceways require 18" depth. |
| 03/21/2022 | WBERGER1 | ZONING | REVIEW | Passed |