Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22BU00014
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/04/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/08/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC Transmittal FROM: Loran Shamis PDSD Zoning Review Section PROJECT: T22BU00014 Cataline Towers - New Spa, and BBQ Area with shade stuctures 2475 N Haskell Dr TRANSMITTAL DATE: August 08, 2022 DUE DATE: August 15, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The proposed use is multifamily residential which is permitted in the O-3 zone (UDC, Table 4.8-3). 1. This comment was not addressed. COMMENT: As you are proposing improvements to a commercial site, an updated Development Package is required (UDC, 3.3.3). See Checklist for Minor Development Changes to Existing Commercial Sites - https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf For questions regarding Zoning comments, please contact me at Loran.Shamis@tucsonaz.gov To resubmit your plans for additional review, please visit: http://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 08/10/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. Comments from the previous electrical plan review were not addressed. There was no written response included with the re-submittal. Please address the previous comments, "Please provide complete electrical power and lighting plans. Include branch circuit and panel designations, grounding for the pool equipment, emergency shut off, panel schedules, indicate clearly all light fixture symbols and correlate with the luminaire schedule". 1 Provide a panel schedule verifying GFI protection for all pool Equipment, Receptacle(s), Lighting as required per NEC 680 Part 2. 2 Provide a grounding detail showing grounding and bonding of all Metallic Structural reinforcement, Ladders, Rails, Fencing, Equipotential Bonding, Motors, Metal Fittings (Components), etc. NEC Part 2. 3 Verify ‘Maintenace Disconnecting Means’ provided for the pool electrical equipment as required per NEC art 680.13. 4 Show wiring methods compliance per NEC art 680.14. 5 Verify receptacle locations comply with NEC art 680.22 were applicable. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. 2012 Tucson/Pima County Outdoor Lighting Code (OLC) |
| 09/13/2022 | JGARCIA1 | BUILDING-COMMERCIAL | REVIEW | Completed |