01/03/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T21PRE0251 - 4857 E GRANT RD -
Site Chipotle Restaurant

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
01/05/2022 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T21PRE0251 – 4857 E Grant Rd

TRANSMITTAL DATE: 1/5/2022



1.COMMENT: A Development Package will be required for this site.

Development package submittal requirements can be found at:

https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

DP16-0225 should be included for reference.

2.COMMENT: Setbacks for Grant Rd (MS&R) are 21’ or Height from the back of existing/future curb. Grant Rd has a proposed width of 120’.

3.COMMENT: Parking for this use is “1 space per 100 sq. ft. GFA and outdoor seating areas” UDC Table 7.4.4-1.

A new parking calculation for the entire site will need to be included in the development package.

Adequate parking is shown for the site on the provided plans.

3.COMMENT: Pedestrian access must also be shown from the building to the pull ahead spaces and to the trash enclosure

4.COMMENT: Since this project is not in a special district there are no façade requirements or restrictions from the city.



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
01/05/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Chipotle
ACTIVITY NO. T21PRE0251
ADDRESS/PARCEL: 4857 E Grant Rd, 110-11-0374
ZONING: C-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
01/05/2022 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is not within a regulatory flood plain.
2. Maximize water harvesting.
Loren Makus
loren.makus@tucsonaz.gov
01/07/2022 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0251

1) Peak hour vehicular trips per ITE 10th edition is 51.36 per 1000 sqft. Given the provided sqaure footage of the building (2534) more than 100 peak hour trips are expected. Per section 6.3.2.1 of the City of Tucson Access Management Guidelines ad Traffic Impact analysis will be required for this development

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
12/28/2021 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
Tucson Fire Department
Michael.Ross2@tucsonaz.gov
520-837-7082