Plan Number: T21PRE0244
Parcel: Unknown

Address:
103 N PARK AV

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0244
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/15/2021 AWARNER1 LANDSCAPE REVIEW Passed
12/15/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0244

1) Confirm with City of Tucson Real Estate, real.estate.tucsonaz.gov, that TRE 2021-062 will still be valid.
2) Assuming this development does not exceed the 25% threshold for full site compliance, DTM has no additional comments
12/15/2021 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
12/16/2021 NMARTEL1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Nicholas Martell, Planner
PROJECT: Thursday Pre-submittal meeting - T21PRE0244
Address: 103 N Park; Parcel 124061470
Zoning: C-2
Existing Use: Mixed Use
Proposed Use: Mixed Use
TRANSMITTAL DATE: December 16, 2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The development is in the Sunshine Mile Urban Overlay District
3. The following uses are permitted in the C-2 zone with the applicable use specific standards:
a. Commercial-Personal Service: 4.9.13.P
b. Commercial-Food Service: 4.9.13.P, 4.9.4.M.1
c. Commercial-Alcoholic Beverage Service: 4.9.13.P
d. Microbrewery as an accessory use to Alcoholic Beverage Service: 4.9.5.E.6, 7, & 8
4. This property is a contributing structure in the Pie Allen Neighborhood
5. Parking and Access will be assessed through the Sunshine Mile UOD.
6. Ensure Signage, Open Space, Streetscape Design and Shade studies are addressed per the UOD.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.
If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov
12/16/2021 LOREN MAKUS ENGINEERING REVIEW Completed No Engineering comments
Loren Makus
loren.makus@tucsonaz.gov
12/17/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T21PRE0244 - 103 N PARK AV - Site Screwbean Brewing Company

1. There is an existing 12-inch cement asbestos water main (PN 006-1983, constructed in 1983) directly under the proposed and previously approval patio seating area in the public right of way. Care will need to be taken to avoid rupturing this old water main.

2. There is an existing 12-inch valve in this existing water main either in, or just south of the proposed patio seating area. Tucson Water's access to this valve may not be obstructed by concrete, paving, or any other permanent features.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
12/21/2021 SBEASLE1 DESIGN PROFESSIONAL REVIEW Needs Review