12/14/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0243

1) Any out of compliance sidewalk along E Old Vail Rd and S Rita Rd will need to be repaired or replaced
12/14/2021 MROSS2 COT NON-DSD FIRE Completed Fire Hydrants
507.5.1 Where required.
Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official.

An S-1 occupancy over 12k sq feet will require an automatic sprinkler system.



Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
12/15/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0243
1. Riparian preservation must meet the requirements of Technical Standard 4-02. The regulatory floodplain must be delineated, and an environmental resource report as described in the standard must be provide and approved.
2. This site will need to meet the requirements for this site for water harvesting and retention/detention. The development of this site should not impact the existing development.
3. Site is in balanced basin. Balanced basin detention and first flush retention must be provided.

Loren Makus
loren.makus@tucsonaz.gov
12/15/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Park Place RV Storage
ACTIVITY NO. T21PRE0243
ADDRESS/PARCEL: 9020 E Old Vail Rd
ZONING: C-2, I-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.
• The entire site would have to brought up to current UDC requirements.
• Minimum 10’ street landscape border is required along Old Vail and Rita Roads.

7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survived.

An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.
• If the set-aside method is used, only inventory and salvage of saguaros is required.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening.
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
12/16/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T21PRE0243
Address: 9020 E Old Vail Rd.
Parcel(s): 14121025F
Zoning: C-2, proposed to be I-2
Existing Use: Vacant
Proposed Use: Personal Storage

TRANSMITTAL DATE: 12/15/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. This site is in the…
3. Personal Storage is an allowed use in the C-2 zone. There are not any exceptions to the dimensional standards and there are two use specific standards for this use the C-2 zone:
a. All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material.
b. The facility's exterior facade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials.
4. If a lot-combo is not proposed the new development must either:
a. Function completely independent of the existing development (no shared entrances, etc.), or
b. Function interdependently with the existing development. Both the existing and new development will be considered one site for the purpose of expansion calculations. The UDC requires that sites that are expanded by 25% or more meet full code compliance.
5. 2 short term bicycle parking spaces are required.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
12/17/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T21PRE0243 - 9020 E OLD VAIL RD - Site Park Place RV and Self Storage

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov