| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/30/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 903.2.3 Group E. An automatic fire sprinkler system shall be provided throughout all Group E Occupancies. Exception: One story buildings when each room used for instruction has at least one exit door directly to the outside at ground level, and when rooms used for assembly purposes have at least one-half of the required exits directly to the exterior ground level, an automatic sprinkler system need not be provided. Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 12/07/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: International School of Tucson ACTIVITY NO. T21PRE0242 ADDRESS/PARCEL: 1701 E Seneca St ZONING: NR-1 UDC 7.6.2. – On sites where the GFA is greater than 10,000 sq.ft. and the expansion is less than 25% the landscape standards apply only to the proposed expansion. 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development submit a landscape plan, Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. A 10’ street landscape border is required along Seneca St. A Design Development Option can be pursued to modify these standards. UDC 3.11.1, if applicable. If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 12/09/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0242 1) No Adverse Comments |
| 12/09/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0242 Address: Parcel 113111010 Zoning: NR-1 Existing Use: Civic-Educational Use Proposed Use: Civic-Educational Use TRANSMITTAL DATE: December 09, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06. 2. The project does not appear to be more than a 25% expansion. 3. The property is in a Neighborhood Preservation Zone (NPZ). NPZ application and compliance are mandatory. 4. Parking is calculated at 1 space per 10 students plus 1 space per 300 square feet of floor area in office use. 5. Setbacks in the NR-1 zone are 10' or 3/4 the height of the structure. Street setbacks are measured at 20' or 1.5 the height of the structure as measured from the street property line, whichever is greater up to a maximum of 90 feet. 6. Height maximums in the zone are 25'. 7. The Jefferson Park Design Manual can be found here: https://www.tucsonaz.gov/files/pdsd/codes/Jefferson_Park_Design_Manual_final.pdf 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
| 12/09/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 300 - 330 pm - T21PRE0242 - 1701 E SENECA ST - SiteGrading International School, modular addition 1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience. 2. If the two new modular buildings required water service, it may be obtained either by connecting to the private on-site water distribution system, or by connecting to the existing 8-inch ductile iron water main on the south side of Seneca St. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 12/09/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Maximize water harvesting in any new landscaped areas. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |