Review Date Reviewer's Name Type of Review Description Status Comments
11/30/2021 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
12/07/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Super Star Car Wash
ACTIVITY NO. T21PRE0241
ADDRESS/PARCEL: 5225 E Speedway Blvd
ZONING: C-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

• 10’ street landscape border is required along Speedway Blvd and Magnolia Ave
• 10’ interior landscape border is required adjacent to residential uses, except as provided in UDC 7.6.4.c.2.

Placing trees along the edge of a parking area or at the ends of parking rows does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survived.

An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
12/09/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0241

1) Any out of compliance sidewalk along E Speedway Bl will need to be repaired/replaced
2) If improvements are proposed (curb along edge of alley) within the public ROW of the existing alley a Private Improvement Agreement will need to be submitted.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
12/09/2021 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T21PRE0241 – 5225 E SPEEDWAY BL

TRANSMITTAL DATE: 11/30/2021



1.COMMENT: A Development Package will be required for this site. Development package submittal requirements can be found at:

https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

2.COMMENT: Automotive washing self-service is permitted in this zone under Automotive, minor service and repair.

3.COMMENT: There are no Use Specific Standards for this use in this zone other than 4.9.13.E :Activity may occur outdoors.

3.COMMENT: Setbacks for Speedway Bl (MS&R) are 21’ or the Height of the wall facing the street.

Height is measured from design grade to top of wall.

MS&R Setback is measured from structure to back of existing/future curb.

If the southern wall of the structure is the feature wall (30’) then the existing location of the structure will not meet setbacks.



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
12/09/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T21PRE0241 - 5225 E SPEEDWAY BL - Site Super Star carwash

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. This parcel is currently served by:
a. A 5/8-inch water meter connected to a ¾-inch water service line connected to the existing 4-inch cement asbestos water main in the alley to the north.
b. A 4-inch fire service line connected to the existing 4-inch cement asbestos's water in the alley to the north.
c. A 1½-inch water meter connected to a 1½-inch water service line connected to the existing 12-inch cement asbestos water main on the north side of Speedway Blvd.
" If the existing 1½-inch water meter and water service line connected to the existing 12-inch water main are too small to supply the proposed car wash's needs, please contact Tucson Water's New Services Section by sending an e-mail to TW_COMMON@tucsonaz.gov to discuss options. Any larger connection will need to the existing 12-inch water main.

3. If the proposed car wash is to be served by an on-site fire suppression sprinkler system, the adequacy of the existing 4-inch water main in the alley to the north will need to be evaluated by Tucson Water via hydraulic modeling. Please contact me to arrange any necessary hydraulic modeling.

4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
12/09/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Maximize water harvesting
2. Setbacks from speedway should be measured from the back of future curb, which look to be 3 ½' in front of current property line.
3. Max driveway width at the property line is 30'

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov