11/24/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Donut Wheel
ACTIVITY NO. T21PRE0234
ADDRESS/PARCEL: 2775 S Wilmot Rd
ZONING: C-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

1. 10' minimum landscape border required along Wilmot, existing vegetation can be used to count towards landscape requirement
2. Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40' of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to mitigate the heat and glare radiated by the built environment, UDC 7.6.1.A.3. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.B.1.a., UDC Technical Standards Manual 5-01-.3.2.


7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survived.

An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.


Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
11/30/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0234

1) Any out of compliance curb, sidewalk, or curb access ramps will need to be updated to current PAG standards. For curb access ramps this includes the use of detectable warnings.
11/30/2021 MROSS2 COT NON-DSD FIRE Approved None


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
12/01/2021 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T21PRE0234 – 2775 S Wilmot Rd

TRANSMITTAL DATE: 11/30/2021



1.COMMENT: A Development Package will be required for this site. Development package submittal requirements can be found at:

https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

2.COMMENT: As per the use specific standard 4.9.4.M.1 “Activities may be conducted outdoors. Loudspeakers or music, live or recorded, shall not be permitted within 600 feet of a residentially zoned property”

3.COMMENT: Loading zone located within a PAAL is not allowed. PAAL on the east of the property can be reduced to 20’ since no parking is located in that area, however the Loading zone cannot be located within that 20’





For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
12/02/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T21PRE0234 - 2775 S WILMOT RD - Site Donut Wheel

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. This parcel is served by an existing 2-inch water service connection, and a 4-inch fire service connection.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
12/02/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Final Plat for Safeway (MP 55 PG 19) shows the project site impacted by a regulatory floodplain. A Floodplain Use Permit will be required.
2. Maximize water harvesting.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov