Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0228
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/12/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 1:30 - 2:00 pm - T21PRE0228 - 1600 E. Tucson Marketplace - Block Plat: Marketplace Lot 6. 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 11/17/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: Marketplace Lot 6 ACTIVITY NO. T21PRE0228 ZONING: PAD-15 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40' of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. Rainwater Harvesting, but not a Commercial Rainwater Harvesting plan, is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 11/18/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0228 1) No adverse comments |
| 11/18/2021 | IMONSHI1 | ZONING | REVIEW | Completed | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T21PRE0228 – 1600 E Marketplace Bl – PAD-15 – Marketplace Lot 6 TRANSMITTAL DATE: 11/16/2021 1.COMMENT: A Development Package and a Block Plat will be required for this site. Development package submittal requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf 2.COMMENT: As per PAD-15, Food and Beverage sales are permitted in sub area A (OCR-2 Zone) 3.COMMENT: Maximum building height for this zone is 60’ 4.COMMENT: Bicycle Parking for each lot will be increased by 10% after their calculation for sub area A according to PAD-15 Section C.2.2.4.II Short Term Bicycle Parking: 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces. Long Term Bicycle Parking: 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 11/18/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | FIRE HYDRANTS 507.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. Exceptions: 1. For Group R-3 and Group U occupancies, the distance requirement shall be 600 ft. 2. For buildings equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the distance requirement shall be 600 feet. Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 11/18/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show how site is complying with the master drainage plan for Tucson marketplace. 2. Maximize water harvesting 3. Any discharge or disturbance to the greyhound wash will require a facility impact permit and review from RFCD. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |