Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0211
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2022 | JPEELDA1 | COT NON-DSD | FIRE | Reqs Change | Building shall be within 600' of a hydrant to the furthest part as the hose lays and or fire sprinklers shall be installed IFC 2018, 507.5.1 Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 08/23/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | |
| 08/24/2022 | AWARNER1 | LANDSCAPE | REVIEW | Passed | |
| 08/24/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 - 300 pm - T21PRE0211 (2nd meeting) - 507 S MEYER Minor Subdivison - Rolling Barrio 1. Tucson Water's New Area Development Unit has no objections to the proposed development, as long as each of the new lots has a minimum of 15' of real property frontage onto S Meyer Avenue, W. Kennedy Street, or S. Convento Avenue. 2. Each of the new lots must have its own water meter. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 08/25/2022 | LSHAMIS1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis, MBA; Lead Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0211 - Rolling Barrio Address: 507 S Meyer Av Parcel(s): 117145170 Zoning: HC-3, HO-3 Existing Use: Vacant Proposed Use: Minor subdivision, single family residential plus guest house TRANSMITTAL DATE: August 25, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-07 - Minor Subdivision. Provide residential plot plans for each site along with the minor subdivision application. Building permits and minor subdivision can be submitted concurrently; however, the building plans will not be approved until the minor subdivision has been approved. 2. Single family residential is a permitted use in HC-3 and HO-3. 3. The site is within a Historic Preservation overlay zone (HPZ); therefore, review and approval from the Historic Preservation Office is required. The following dimensional standards relate to the underlying zoning and may be differ from the requirements of the Historic Preservation overlay zone. Contact Jodie Brown for more information (Jodie.Brown@tucsonaz.gov). 3.a. There is no minimum lot size for C-3; the minimum lot size for O-3 is 5,000 square feet (UDC 6.3.4). 3.b. The maximum permitted height for C-3 is 75'; the maximum permitted height for O-3 is 25' (UDC 6.3.4). 3.c. The minimum perimeter yard setback residential uses adjacent to non-residential zones in C-3 is 0'; the minimum perimeter yard setback for O-3 is the greater of 10' or 3/4 the height of the proposed building wall height. Based on the 14'9' wall height the SFR models within the O-3 zone, the minimum perimeter yard setback should be 11' from the structure to the property line. 4. The parking ratio is 2.25 parking spaces per single family dwelling unit. If the guest houses meet the criteria to qualify as an Accessory Dwelling Unit (ADU), only 1 parking space is required per guest house. See ADU standards in UDC 6.6.3.B. 5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
| 08/25/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. No comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 08/30/2022 | FRANK PODGORSKI | HPZ ADVISORY BOARD | HPZ ADVISORY BOARD DATE | Needs Review |