Plan Number: T21PRE0205
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0205
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2021 MROSS2 COT NON-DSD FIRE Completed An automatic sprinkler system may be required depending on occupancy classification and storage size.

-903.2.9.1 Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406.8 of the International Building code, as shown:
4. A Group S-1 fire area used for the repair of commercial motor vehicles where the fire area exceeds 5,000 square feet.

903.2.9.2 Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 20,000 cubic feet shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
10/13/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: Tucson Southern Tire Mart
ACTIVITY NO. T21PRE0205
TRANSMITTAL DATE: October 13, 2021

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

The 25% expansion calculation is important as no landscape would be required if the expansion is 25% or less. If it greater than 25% expansion, the whole site would have to be brought up to the current code.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening

If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
10/13/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0205

1) Depending on the 25% expansion threshold is triggered full site compliance would be required. The majority of the ROW looks to be designed to current standards however at several entrances curb and sidewalk have been damaged. Damaged or out of compliance sections will need to be replaced. Please look at modifying the radius or making other changes to the driveways to afford better ingress/egress for the vehicles using the site. This would mitigate future issues
10/14/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T21PRE0205
Address: 5570 E TRAVEL PLAZA WY
Parcel(s): 140-37-068J
Zoning: C-2
Existing Use: Vacant
Proposed Use: Automotive, Major Service and Repair

TRANSMITTAL DATE: 10/14/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The Development Package will need to encompass the entire site.
3. Parking will be required at 1 space/300 SF of GFA. The building is proposed to be 8,500 SF, requiring 28 parking spaces. Parking requirements will need to be met for the existing development as well.
4. Pedestrian connection will be required to all adjacent ROWs and to all public access areas. You may just connect to the existing development if it connect to the ROW.
5. If this is an expansion of 25% or more the whole site will need to meet full code compliance.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
10/14/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T21PRE0205 - 5570 E TRAVEL PLAZA WY - SiteGrading Tucson Southern Tire Mart

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
10/14/2021 SBLOOD1 ENGINEERING REVIEW Completed No Comments

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov