Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0205
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/12/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | An automatic sprinkler system may be required depending on occupancy classification and storage size. -903.2.9.1 Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406.8 of the International Building code, as shown: 4. A Group S-1 fire area used for the repair of commercial motor vehicles where the fire area exceeds 5,000 square feet. 903.2.9.2 Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 20,000 cubic feet shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@tucsonaz.gov |
10/13/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Tucson Southern Tire Mart ACTIVITY NO. T21PRE0205 TRANSMITTAL DATE: October 13, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. The 25% expansion calculation is important as no landscape would be required if the expansion is 25% or less. If it greater than 25% expansion, the whole site would have to be brought up to the current code. Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
10/13/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0205 1) Depending on the 25% expansion threshold is triggered full site compliance would be required. The majority of the ROW looks to be designed to current standards however at several entrances curb and sidewalk have been damaged. Damaged or out of compliance sections will need to be replaced. Please look at modifying the radius or making other changes to the driveways to afford better ingress/egress for the vehicles using the site. This would mitigate future issues |
10/14/2021 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0205 Address: 5570 E TRAVEL PLAZA WY Parcel(s): 140-37-068J Zoning: C-2 Existing Use: Vacant Proposed Use: Automotive, Major Service and Repair TRANSMITTAL DATE: 10/14/2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The Development Package will need to encompass the entire site. 3. Parking will be required at 1 space/300 SF of GFA. The building is proposed to be 8,500 SF, requiring 28 parking spaces. Parking requirements will need to be met for the existing development as well. 4. Pedestrian connection will be required to all adjacent ROWs and to all public access areas. You may just connect to the existing development if it connect to the ROW. 5. If this is an expansion of 25% or more the whole site will need to meet full code compliance. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |
10/14/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T21PRE0205 - 5570 E TRAVEL PLAZA WY - SiteGrading Tucson Southern Tire Mart 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
10/14/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | No Comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |