Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0199
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/28/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 507.1 Required water supply. An approved water supply capable of supplying the required fire flow for the protection shall be provided to premises on which facilities, buildings or portions of buildings are hereafter constructed or moved into or within the jurisdiction. 507.3 Fire Flow. Fire-flow requirements for buildings or portions of buildings and facilities shall be in accordance with Appendix B of the IFC. FIRE HYDRANTS 507.5.1 Where required. Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. Exceptions: For Group R-3 and Group U occupancies, the distance requirement shall be 600 ft. For buildings equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the distance requirement shall be 600 feet. Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 09/30/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Quik Trip ACTIVITY NO. T21PRE0199 TRANSMITTAL DATE: September 30, 2021 PAD-21 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. Landscape and border requirements shall be in accordance with the Valencia Crossing PAD 7.7. Native Plant Preservation An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval. Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
| 10/05/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Site must comply with updated retention detention manual. 2. Maximize water harvesting. 3. Valencia Crossing Drive must be developed to the full width for the extent of this development. 4. Driveways must have 25-foot minimum curb return radii on East Valencia Road and 18-foot radii on Valencia Crossing Drive. 5. The nearest driveway must be 150 feet from the signalized intersection. Loren Makus Loren.makus@tucsonaz.gov |
| 10/05/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T21PRE0199 - 5050 E VALENCIA RD - Site QuikTrip Store 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 10/06/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0199 Address: Parcel: 140360180 Zoning: PAD-21 Existing Use: Vacant Proposed Use: Retail-General Merchandise Sales TRANSMITTAL DATE: October 06, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06-Development Package. 2. The provided address on the application, 5050 E Valencia, is not correct. 3. The proposed project is in planning area A. General Merchandise Sales is a permitted use. 4. Refer to page 47 of the PAD regarding shared parking. Parking stall counts shall be calculated across the Valencia Crossing as a whole. Each permitted building must provide at least 80% of their required parking from the UDC. The parking count on the sample site plan is sufficient. 5. Short term bicycle parking is required at 1 space per 5,000 sq ft. GFA; Long term bicycle parking is calculated at 1 space per 12,000 sq ft. GFA with a 2-space minimum. According to the PAD (pg. 47), short term parking shall be within 75' of a public entrance. Long-term spaces may be substituted for short term on a two for one basis up to a maximum of 50 percent of the required short-term spaces. 6. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
| 10/07/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0199 1) A Traffic Impact Analysis will be required for this development. For this type of use about 16 trips per hour per vehicle fueling station are expected. This development has 8 stations (not including the dedicated diesal). Refer to City of Tucson Access Management Guidelines section 6.3.2 2) Vehicular access points will need to be radiused and meet Access Management Guidlines for spacing 3) New 6' sidewalk alond E Valencia Rd, and New 5' sidewalk and Curb will need to be provided along Valencia Crossing Dr John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |