Plan Number: T21PRE0187
Parcel: Unknown

Address:
941 N STONE AV

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0187
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2021 MROSS2 COT NON-DSD FIRE Completed A fire alarm system will be required.

903.2.8 Group R.
An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area.

Aerial Fire Apparatus Access Roads
D105.1 Where required.
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided.

D105.2 Width.
Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.

D105.3 Proximity to building.
One or more of the required access routes meeting this condition shall be located not less than 15 feet and not greater than 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official.


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
09/20/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: Stone Ave. Multi-family
ACTIVITY NO. T21PRE0187
TRANSMITTAL DATE: September 20, 2021

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

" A 10' street landscape buffer is required along Stone Ave and Ash Ave
" The parking area will require 1 tree for every 4 parking space to be planted adjacent or within the parking area to maximize shade to mitigate the heat island effect.
" The parking area will require a 5' screen adjacent to Ash Ave.

7.7. Native Plant Preservation
An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.


If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
09/21/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0187
1. Ash Avenue is a named alley/street only north of 1st Street in this location.
2. Site is impacted by the West University Wash floodplain. The floodplain delineation must be updated for this location.
3. Stone Avenue is an arterial with a future width of 120 feet.
4. Maximize water harvesting.
Loren Makus
loren.makus@tucsonaz.gov
09/22/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T21PRE0187 - 941 N STONE AV - Site Stone Ave. Apartments, 19 units

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. There is an existing 12" PVC water main in Stone Avenue that can provide water to the proposed development. The water pressure in this main is in the 48 to 55 psi range.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
09/23/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T21PRE0187
Address: 941 N STONE AV
Parcel(s): 117-02-1920
Zoning: C-3
Existing Use: Vacant
Proposed Use: Multifamily

TRANSMITTAL DATE: 09/23/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. This site is in the Infill Incentive District and may be able to get some relief on some zoning requirements.
3. Stone Ave. is proposed to be widened to 120' and is currently at 80', 20' will be taken from each side of the road.
4. This site is on a major street and route and requires a setback of 21' from the back of the future curb location.
5. A Back-up Spur will be required on the eastern side of the parking lot.
6. Where parking spaces are proposed to be 15'-6", clearance of 2'-6" will be required on any adjacent sidewalk.
7. Pedestrian circulation is required to all adjacent right of ways.
8. N Ash Ave. does not appear to be a named alley, if it is not a named alley it will not be able to be used for primary access.
9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
09/28/2021 SBEASLE1 COT NON-DSD TRAFFIC Needs Review