09/07/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T21PRE0183 - 1875 W VALENCIA RD - Site: Dollar Self Storage Expansion

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
09/08/2021 MROSS2 COT NON-DSD FIRE Completed 507.1 Required water supply.

An approved water supply capable of supplying the required fire flow for the protection shall be provided to premises on which facilities, buildings or portions of buildings are hereafter constructed or moved into or within the jurisdiction.

507.3 Fire Flow.
Fire-flow requirements for buildings or portions of buildings and facilities shall be in accordance with Appendix B of the IFC.

D104.1 Building exceeding three stories or 30 feet in height.
Buildings or facilities exceeding 30 feet or three stories in height shall have not fewer than two means of fire apparatus access for each structure.

D104.3 Remoteness.
Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. Aerial Fire Apparatus Access Roads

D105.1 Where required.
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided.

D105.2 Width.
Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.

D105.3 Proximity to building.
One or more of the required access routes meeting this condition shall be located not less than 15 feet and not greater than 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official.

An automatic fire sprinkler system will be required.

A fire alarm system will be required.



Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
09/08/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: Dollar Self Storage,
ADDRESS: 1875 W Valencia Rd,138-24-022L
ACTIVITY NO. T21PRE0183
TRANSMITTAL DATE: September 9, 2021

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

A 10’ street landscape border will be required along S Headley Rd. Some of the existing plants can be counted towards the street border requirements if they are healthy enough.

The parking area will require 1 tree per 4 parking spaces.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening

If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
09/09/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0183

1) New 5' wide sidewalk along Headly Rd will need to be provided along with curb access ramps as needed
2) Existing driveways will need to meet current PAG detail 206 design standard
09/09/2021 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T21PRE0183 – Dollar Self Storage Expansion - C-2 Zone

TRANSMITTAL DATE: 09/07/2021



1.COMMENT:A Development Package will be required for this project. Information on the development package submittal requirements can be found at

https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf



Once the development package is approved then zoning can approved the commercial building plans.



2.COMMENT: The site is comprised of two parcels. Zoning cannot approve the plans if structures are encroaching on existing property lines. A lot combination may be required.

3.COMMENT: Clarify if both structures will be used for personal storage or only if building A is being used as personal storage. Parking calculations will be altered based on the Gross Floor Area used for personal storage.



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/09/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Maximize water harvesting in any new landscape areas.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov