| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/07/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T21PRE0181 - 5075 S MIDVALE PARK RD - Site: Mister Car Wash 1. Tucson Water's New Area Development Unit has no objections to the proposed development 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 09/08/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | No comments Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@Tucsonaz.gov |
| 09/08/2021 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0181 Address: 5075 S Midvale Park Rd. Parcel(s): 13731373A Zoning: C-2 Existing Use: Automotive, Minor Service and Repair Proposed Use: Automotive, Minor Service and Repair TRANSMITTAL DATE: 09/08/2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Per rezoning C9-12-14, rezoning condition 21 “There shall be no more than 2 vehicle-parking spaces for the proposed use.” Zoning will not support the proposal unless the applicant pursues changing the rezoning conditions, for more info on amending the rezoning conditions reach out to John Beall at john.beall@tucsonaz.gov or at 791-5550. 3. If rezoning conditions are changed, the process to change the conditions must be completed prior to the issuance of a development package. Additionally, the development package will be required to be issued prior to the building permit’s issuance, however, reviews may be conducted concurrently. 4. A 24’ PAAL is required for 90-degree parking. 5. 90-degree parking is required to be 8.51’ in width and 18’ long. 6. 1 van accessible ADA space will be required. 7. Provide an expansion calculation. If the site is proposing an expansion of 25% or more the site will need to be brought up to code. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |
| 09/08/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Mister Car Wash ACTIVITY NO. T21PRE0181 TRANSMITTAL DATE: September 9, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. A 10’ street landscape border is required along S Midvale Park Rd. Depress all new landscape areas at least 6” to provide water harvesting on site. Trees in parking areas are required at a ratio of 1 tree per 4 parking spaces. If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
| 09/09/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0181 1) Driveway spacing does not adhere to City of Tucson Access Management Guidelines section 5.4, for both the proposed driveway compared to the existing onsite driveway and the adjacent property driveway. The number of driveways for this parcel off S Midvale Park Rd is limited to one John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 09/09/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. New impervious area must be provided with balanced basin detention and first flush retention as per new detention/retention manual https://www.tucsonaz.gov/pdsd/codes-plans. 2. There isn't enough space for a new driveway in between the driveway on site and the neighboring driveway just south of the site. 3. Maximize water harvesting in any proposed landscaping. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |