Plan Number: T21PRE0175
Parcel: Unknown

Address:
2101 N ORACLE RD

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0175
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2021 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section

PROJECT: T21PRE0175 – Commercial storage- C-2 Zone

TRANSMITTAL DATE: 08/25/2021


1.COMMENT: A Development Package will be required for this project. Information on the development package submittal requirements can be found at

https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

Once the development package is issued then the commercial building plans that are consistent with the development package can be issued.

2.COMMENT: Show the setback dimension from the structure to 13th St.

3.COMMENT: Parking area access lane must be at least 24’ wide. Pedestrian access through the site is required specifically showing access from the parking to the entrance of the structure.

4. COMMENT: Parking calculations for Commercial storage is 1 per 5,000sq.ft. GFA which calculated to 2.5. Additional parking spaces may be required.

5. Setbacks along Oracle are 21ft or the height of the structure measured from the back of future curb. Setbacks along Flores are 21ft or the height measured from outside edge of nearest travel lane. Show conformance with these standards.

For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
08/25/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: Villegas Commercial Storage
ACTIVITY NO. T21PRE0176
TRANSMITTAL DATE: August 25, 2021

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

A 10' street landscape border is required along all streets. A 5' wall and a 10' landscape border is required adjacent to the multi-family on the north side of the property.

7.7. Native Plant Preservation
An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening

If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
08/25/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Show the complete pedestrian circulation path out to each frontage road and to the proposed trash enclosure.
2. 5' sidewalk will need to be installed along both N 13th Av and W Flores St, and if the sidewalk along N Oracle Rd is less than 4' it will need to be widened to 6'.
3. Maximize water harvesting.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
08/25/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 150 - 210 pm - T21PRE0175 - 2101 N ORACLE RD - Site Villegas Commercial Storage

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. There is an existing 8" cement asbestos water main (PN 045-1963) in N 13th Avenue, that feeds two (2) ¾" water service lines located on the west side of the parcel.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
08/26/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0175

1) New 5' wide sidewalk along W Flores St and N 13th Av, along the project frontage will be required
2) New curb access ramps at N 13th Av/W Flores St and W Flores St/N Oracle Rd will be required per PAG detail 207
3) Proposed access driveways will be constructed per PAG detail 206
4) Access drive off of N 13th av need to be a minimum of 6' away from the adjacent property line

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
08/26/2021 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
Tucson Fire Department
Michael.Ross2@tucsonaz.gov
520-837-7082