Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T21PRE0161
Parcel: Unknown

Address:
665 N FREEWAY

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T21PRE0161
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/03/2021 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
08/03/2021 ANY CONSTRUCTION ESTIMATE REVIEW Active
08/03/2021 BILLIE LEE COMMENTS COMMENTS Active
08/04/2021 LOREN MAKUS ELECTRICAL ENGINEERING REVIEW Completed 1. Water harvesting must be maximized as part of this rezoning.
08/04/2021 NICHOLAS ROSS ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nick Ross; Principal Planner
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T21PRE0161
Address: 665 N. Freeway
Parcel(s): 11616301H
Existing Zoning: I-1
Proposed Zoning: C-1
Existing Use: Traveler's Accommodation
Proposed Use: Multi-family

TRANSMITTAL DATE: August 4, 2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Development standards: 30 ft building height
3. Proposed use and use-specific standards: n/a
4. Perimeter yard setbacks: 0 ft
5. Applicable overlays: n/a
6. Major Streets and Routes Plan: Saint Marys Rd - Arterial - 100 ft
7. Applicable street setbacks: 21 ft or building wall height as measured from back of future curb
8. Parking requirements: 1.25 spaces per dwelling unit. 112 units * 1.25 spaces = 140 required spaces
9. Bike parking requirements: .10 short-term spaces per bedroom, .5 long-term spaces per bedroom
10. Loading space requirements: n/a
11. Landscape requirements can be discussed further with Anne Warner at anne.warner@tucsonaz.gov
12. Additional comments: Recommend attending CDRC Pre-Submittal meeting to get feedback from Fire, Engineering and other reviewers.
13. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at nicholas.ross@tucsonaz.gov.
08/05/2021 MROSS2 FIRE REVIEW Completed - An automatic fire sprinkler system and fire alarm system will be required.


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov