Plan Number: T21PRE0156
Parcel: Unknown

Address:
1002 E 36TH ST

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0156
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/27/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: SFR at the Bridges
ACTIVITY NO. T21PRE0156
TRANSMITTAL DATE: July 27, 2021
DUE DATE: July 29, 2021

Generally, UDC 7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

Specifically, adherence to the requirements in The Bridges PAD

If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
07/27/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 150 - 210 pm - T21PRE0156 - 1002 E 36TH ST - Site The Bridges Sub-area B-1

1. Tucson Water's New Area Development Unit generally has no objections to the proposed development and offers the following comments for your convenience.

2. The design of the potable water distribution system to serve the proposed lots will need to be reviewed and approved via Tucson Water's Master Water Plan and Design Plan processes.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
07/27/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: SFR at the Bridges
ACTIVITY NO. T21PRE0156
TRANSMITTAL DATE: July 27, 2021
DUE DATE: July 29, 2021

Generally, UDC 7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

Specifically, adherence to the requirements in The Bridges PAD

If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov
07/28/2021 MROSS2 COT NON-DSD FIRE Completed -Fire hydrants are required throughout per section 507.5 of the 2018 IFC



Michael Ross
Fire Inspector
TFD Fire Prevetion division
520-837-7082
Michael.Ross2@tucsonaz.gov
07/29/2021 LSHAMIS1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Planner, MBA

PROJECT: Thursday Pre-submittal meeting - T21PRE0156
Address: 1002 E 36th St
Parcel(s): 13213066B
Zoning: PAD-15, subarea B-I
Existing Use: Vacant
Proposed Use: Single Family Residential Subdivision, Final Plat (?)

TRANSMITTAL DATE: July 29, 2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-07 - Final Plat.
2. A tentative plat is required with submittal to demonstrate future development compliance per PAD-15, Section C.2.3, Table F (page 63).
3. The proposed use is single family residential which is a permitted use in PAD-15, subarea B-I.
4. Demonstrate the 150' neighborhood transition zone required along 36th per PAD-15, page 57.
5. For medium density detached residential demonstrate the lot sizes are at least 1,500 square feet and at least 30' wide per PAD-15, Section C.2.3, Table F (page 63). For medium density attached residential demonstrate the lot sizes are at least 850 suare feet and at least 20' wide per PAD-15 (page 63).
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
07/29/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0156

1) An update TIA will be required per City of Tucson Access Management Guidelines
2) A PIA is required for the construction of the proposed public roads

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
07/30/2021 LOREN MAKUS ENGINEERING REVIEW Completed 1. Provide copies of PAD appendix D to show how street section complies.
2. Meet PAD requirements.
3. Maximize water harvesting.