Plan Number: T21PRE0151
Parcel: Unknown

Address:
411 E 4TH ST

Review Status: Active

Review Details: PREAPPLICATION MEEETING

Plan Number - T21PRE0151
Review Name: PREAPPLICATION MEEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/27/2021 NICHOLAS ROSS ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nick Ross
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T21PRE0151
Address: 411 E. 4th St
Parcel(s): 117-03-321H
Existing Zoning: PAD(H)-31
Proposed Zoning: PAD(H)-31
Existing Use: Religious
Proposed Use: Single Family Attached/Multifamily Development

TRANSMITTAL DATE: 7/27/21

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. PAD(H)-31 appears to be silent on Use-specific standards which means UDC applies. The proposal calls for attached single family residential which requires compliance with Use-Specific Standards 8.7.3 (FLD).
3. If it is intended to amend the PAD document to allow attached single family residential without complying with UDC Section 8.7.3, Zoning will review and provide comments during the Minor or Major Amendment process.
4. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at nicholas.ross@tucsonaz.gov.
07/27/2021 BILLIE LEE COMMENTS COMMENTS Active
07/27/2021 MROSS2 FIRE REVIEW Completed D104.1 Building exceeding three stories or 30 feet in height.
Buildings or facilities exceeding 30 feet or three stories in height shall have not fewer than two means of fire apparatus access for each structure.

D104.3 Remoteness.
Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses.

Aerial Fire Apparatus Access Roads

D105.1 Where required.
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided.

D105.2 Width.
Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.

D105.3 Proximity to building.
One or more of the required access routes meeting this condition shall be located not less than 15 feet and not greater than 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official.


Michael Ross
Fire code inspector
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
07/27/2021 ANY CONSTRUCTION ESTIMATE REVIEW Active
07/27/2021 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
07/28/2021 LOREN MAKUS ELECTRICAL ENGINEERING REVIEW Completed PDSD Engineering has no comment.
Loren Makus
loren.makus@tucsonaz.gov