Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0146
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/06/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Self Storage ACTIVITY NO./ADDRESS: T21pre0146, 5642 S ALVERNON WY TRANSMITTAL DATE: July 1, 2021 DUE DATE: July 15, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. 7.7. Native Plant Preservation An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval. UDC Technical Standards Manual - Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
07/09/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T21PRE0146 1. Maximize water harvesting. 2. Provide balanced basin detention and first flush detention in accordance with detention/retention manual adopted earlier this year. 3. Demonstrate ability of service vehicles to access solid waste containers. Loren Makus loren.makus@tucsonaz.gov |
07/12/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 1. An automatic sprinkler system shall be provided throughout all S-1 buildings over 12,000 square feet. 2. A fire alarm system will be required. 3. A fire hydrant is required within 400' of all exterior portions of all buildings. That distance shall be increased to 600' for buildings equipped with an automatic sprinkler system. 4. Water supply must be shown to meet the required Fire Flow for the buildings. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
07/13/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | 230 - 250 pm - T21PRE0146 - 5642 S ALVERNON WY - Site Self-Storage - Tucson 1. This proposed development is located outside Tucson Water's Service Area. Please contact The Ray Water Company at 520-448-3737 with any questions you may have about obtaining drinking water service for this proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
07/14/2021 | LSHAMIS1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; Planner, MBA PROJECT: Thursday Pre-submittal meeting - T21PRE0146 Address: 5642 S Alvernon Way Parcel(s): 14005033H Zoning: C-2 Existing Use: Vacant Proposed Use: Self Storage and RV Storage Facility TRANSMITTAL DATE: July 14, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Parcels 14005033H and 14005032D are zoned C-2 and personal storage is a permitted use in this site, use specific standards 4.9.10.C.3 and .6. a. 4.9.10.C.3 - All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material b. 4.9.10.C.6 - The facility's exterior façade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials. 3. Lots 14005032G, 14005032F, and 14005032E are zoned R-1 and Personal Storage is not permitted in this zone. Rezoning case, C9-19-19, for these parcels has been Authorized, contact Mark Castro in the Entitlements Section to confirm there is nothing left to complete regarding the rezoning prior to submitting the formal Development Package. Reference the Rezoning case on Property Research Online (PRO) to view rezoning conditions. 4. A lot combination processed by Pima County may be required. 5. The setback from Felix Blvd is 20' or the height of the adjacent wall, the greater applies, measured from the property line to the exterior, adjacent wall. 6. Demonstrate compliance with the following parking calculation - the parking calculation for personal storage is 0 for storage units, if the storage units have direct vehicular access, and a minimum of 2 spaces for any associated office. 1 space per 4,000 sq ft gross floor area, if the storage units do not have direct vehicular access, and a minimum of 2 spaces for any associated office. 7. Two-way access or PAAL for storage use development is a minimum of 30' wide. 8. 2 short term bicycle parking spaces are required for this proposed development. 9. 2 Type A loading areas are required for this proposed development. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
07/15/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0146 T21PRE0146 1) The proposed driveway off S Alvernon Wy exceeds the maximum allowable driveway width of 35' as found in City of Tucson Access Management Guidelines 2) The proposed driveway off S Alvernon Way. North bound traffic on Alvernon cannot turn left or perform a U-turn at this location. The proposed driveway entrance needs to be a right-in-right-out configuration with a pork chop 3) Per City of Tucson Access Management Guidelines, Section 5.11, the minimum driveway throat length should be 60' off S Alvernon Wy. Sufficient onsite maneuvering for the maximum design vehicle cannot interfere with S Alvernon Wy 4) There appears to be a fence on the West side of S Alvernon way constructed to prevent pedestrians from crossing to the Elementary School on the east side. Please coordinate with Sunnyside School District 5) Provide new 6' wide sidewalk along S Alvernon Way for the projects frontage, including curb access ramps at the proposed driveway 6) Provide new curb and 5' sidewalk along E Felix Bl for the projects frontage. This will be accomplished through a PIA 7) Standard details apply including for driveway radii and width 8) If a rezoning occurred, then a TIA would have been required. If it is more than 2 years old, per access management guidelines section 6.3.2 a new TIA is needed John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |