| 07/07/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Salad and Go ACTIVITY NO./ADDRESS: T21pre0145, 1302 S KOLB RD TRANSMITTAL DATE: July 6, 2021 DUE DATE: July 15, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. UDC Technical Standards Manual - Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
| 07/09/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Site is not within a mapped flood hazard area. 2. Pedestrian route cannot cross drive-through stacking area. 3. Maximize water harvesting. Loren Makus loren.makus@tucsonaz.gov |
| 07/12/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 07/13/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 210 - 230 pm - T21PRE0145 - 1302 S KOLB RD - Site Salad and Go Restaurant 1. Tucson Water's New Area Development Unit generally has no objections to the proposed development and offers the following comments for your convenience. 2. Tucson Water's records indicated Two ¾" copper water service lines extend from the existing 24" concrete cylinder water main in Kolb Rd (PN 019-1968) onto this parcel. One of these water service lines is being used by the existing Jack In The Box Restaurant. The other appears to be currently unused. 3. No additional water service line connections may be made to the existing 24" concrete cylinder water main in Kolb Rd. 4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 07/14/2021 | LSHAMIS1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; Planner, MBA PROJECT: Thursday Pre-submittal meeting - T21PRE0145 Address: 1302 S Kolb Rd Parcel(s): 13502134D Zoning: C-2 Existing Use: Vacant Proposed Use: Commercial use - food services TRANSMITTAL DATE: July 15, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The site is zoned C-2 and the proposed use is food service, use-specific standards 4.9.4.M.1 and 4.9.13.P are applicable. 3. A lot line reconfiguration may be required due to development associated with this proposal encroaching onto 13502134M. A cross access agreement may also be used to address vehicular use on another parcel. 4. Demonstrate the shopping center is meeting parking requirements with the proposed development. The parking calculation for a shopping center is 1 space per 300 square feet of gross floor area. 5. The proposed project requires two long-term bicycle parking spaces. 6. Kolb is a Major Street and Route and developing area setbacks are applicable. The setback requirement is 21' or the height of the adjacent wall, the great of which is applicable, measured from the exterior adjacent wall to the back of the existing or future curb. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
| 07/15/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0145 1) Per City of Tucson Access Management Guidelines, Section 5.11, the minimum driveway throat length should be 60'. The driveway inbound and outbound on the northside of the building need to be adjusted to the west, so the minimum distance from Kolb Rd is maintained 2) The exit only onto Kolb Rd will need to be adjusted so it has a width of 15' to preclude vehicles from entering off Kolb. The existing driveway will need to be re-constructed to meet current PAG 206 details John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |