Plan Number: T21PRE0144
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0144
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2021 AWARNER1 LANDSCAPE REVIEW Passed
07/09/2021 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is not within a mapped flood hazard area.
2. Parcel was created by a platted subdivision. Creation of three parcels requires a subdivision plat.
3. Access must be developed as a street or PAAL. (UDC 7.8.4.C)
4. This land division likely meets the requirement for a minor subdivision.
Loren Makus
loren.makus@tucsonaz.gov
07/12/2021 MROSS2 COT NON-DSD FIRE Completed Fire department access roads need to be at least 20' wide.
Dead end access roads over 150' shall be provided with an approved turnaround in accordance with Table D103.4 of the 2018 IFC.


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
07/13/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 150 - 210 pm - T21PRE0144 - 914 S MAGNOLIA AV - SiteLand Split Frohberg Development

1. Each of the three proposed lots MUST have a separate water meter, as they will be under different ownership. And a separate water meter for each of the six residences is strongly recommended.

2. To comply with Tucson Water's Remote Meter Policy, that prohibits water service lines from being run across property that will be under different ownership in private water line easements:
a. Each of the three proposed lots must have a minimum of 15' of actual real property frontage on the existing 6" cement asbestos water main in Magnolia Ave (WO 3201). i.e. The westernmost and middle lot would need to be reconfigured as "flag pole" lots that front the existing water main in Fremont Ave, OR
b. An acceptable alternative to creating such "flag pole" lots would be to widen the vehicular access and utility easement, dedicate it as a public utility easement, and construct a new 4" dead-end public water main within this easement from the existing 6" cement asbestos water main in Magnolia Avenue to the westernmost lot. Note: As sewer lines and other underground utilities will also need to be placed within this easement, the public utility easement will probably need to be significantly wider than 15 feet wide. The minimum allowable horizontal separation between a water line and a wastewater sewer collection line is 6 feet, from outside edge to outside edge.

3. The design of the new public water main would need to be reviewed and approved within Tucson Water's Water Master Plan and Design Plan Review Processes.

4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
07/15/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0144

1) Assuming this development requires a minor subdivision process;
a. Driveway connection to S Magnolia Av will need to be a PAG standard Apron
b. Provide New 5' wide sidewalk along property's frontage on S Magnolia Av

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
07/15/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers; Planner

PROJECT: Thursday Pre-submittal meeting T21PRE0144
Address: 914 S Magnolia
Parcel(s): 128141220
Zoning: R-1
Existing Use: SFR
Proposed Use: Minor Subdivision

TRANSMITTAL DATE: 0715/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section Section 2-07.0.0: Final Plat, Block Plat, Minor Subdivision, and Condominium Plat Applications.
2. A Design Development Option will be required to permit the 3’ setback on the existing 3-bedroom dwelling.
3. Sites that require 5 more parking spaces are required to provide commercial type parking.
4. Long Term and Short Term rental are both permissible.
5. The proposal is adequate to proceed with submittal of a Minor Subdivision application.
6. A Minor Subdivision does not require a Tentative Plat and can go straight to a Final Plat.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Minor Subdivision review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at samuel.rogers@tucsonaz.gov or (520) 837-6932.