Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0141
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: ACTIVITY NO./ADDRESS: T21pre0141 TRANSMITTAL DATE: July 6, 2021 DUE DATE: July 15, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. UDC Technical Standards Manual - Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
| 07/09/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. This site is not within a flood hazard area. 2. Maximize water harvesting. 3. The new solid waste enclosure requires the service truck to use a very busy traffic area to service the container. We recommend finding a different orientation or location so the container is serviced from a lower traffic area. Loren Makus loren.makus@tucsonaz.gov |
| 07/12/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 07/13/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 150 pm - T21PRE0141 - 2630 S KOLB RD - Site Starbucks 1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience. 2. There are existing water mains in the parking area access lanes north and south of the proposed development. Care must be taken during any excavation in these areas. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 07/15/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0141 1) No Adverse comments. Standard details apply |
| 07/20/2021 | SBEASLE1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0141 Address: 2630 S Kolb Rd. Parcel(s): 13624450A Zoning: C-2 Existing Use: Food Service Proposed Use: Food Service TRANSMITTAL DATE: COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. New construction will require a Development Package that encompasses the entire site. 3. The development package must be issued prior to the issuance of any building permits, but the building permit may be submitted for review at any time. 4. The site may be considered a “Shopping Center” if no more than 50% of the floor area is dedicated to uses with a parking formula of one space per 100 square feet of gross floor area or a more intense formula. Provide a floor area calculation of the different uses on the parcel if the site is considered a Shopping Center. 5. Food service is allowed in in the C-2 zone and is subject to Use-Specific Standards 4.9.4.M.1 and 4.9.13.P 6. 4.9.4.M.1 - Activities may be conducted outdoors. Loudspeakers or music, live or recorded, shall not be permitted within 600 feet of a residentially zoned property. 7. If the site is considered Shopping Center parking will be required at 1 space per 300 sqft of GFA. If the site is not considered a Shopping Center food service is required to provide parking at 1 space 100 sqft of GFA. 8. Short Term Bicycle parking is required at 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces. 9. Long-Term Bicycle parking is required at 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |