Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0138
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2021 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/NPPO Review PROJECT: Columbus Park ACTIVITY NO./PARCEL: T21pre0138, 103-04-001R TRANSMITTAL DATE: July 1, 2021 DUE DATE: July 8, 2021 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. 7.7. Native Plant Preservation An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval. UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner at email anne.warner@tucsonaz.gov |
| 07/06/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 07/07/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T21PRE0138 1. Mapped floodplain is more extensive than shown on plans. Mapped boundaries will govern compliance until a LOMR is approved by FEMA and reaches the effective date. loren.makus@tucsonaz.gov |
| 07/08/2021 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0138 Address: 3495 W EL CAMINO DEL CERRO Parcel(s): 10304001R Zoning: RX-1 Existing Use: Regional Park Proposed Use: Regional Park COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Building permits may be submitted at any time, however, a Development Package will be required to be issued prior to the issuance of any building permits. 3. The proposed use is Regional Park and is subject to Use-Specific Standards 4.9.13.B and C 4. The principal use is restricted to hours of operation of 7:00 a.m. to 10:00 p.m. 5. In addition to the requirements of Section 6-101, Outdoor Lighting Code, of the Tucson Code, any outdoor lighting utilized in conjunction with the use shall be located and directed so as to eliminate glare toward streets and adjoining R-3 or more restrictive zoning. 6. If any structures are proposed they must comply with the setback standards for the RX-1 zone (20' on non street lot lines). 7. Parking is required at 15 spaces per field. 8. Bicycle parking is required at 2 spaces per field. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |
| 07/08/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 150 pm - T21PRE0138 - 3495 W EL CaminoDelCerro - SiteGradingSwpppFloodplain Columbus Park 1. Tucson Water's New Area Development Unit generally has no objections to the proposed development, and offers the following comments for your convenience. 2. The provided site plan contained no legend that identifies every symbol shown on the plan, and no list of construction notes that explains the meanings of the numerous construction note symbols on the site plan. Therefore, some of the details of the proposed development are not clear to this reviewer. 3. The future concrete box culvert drainage structure will cross a 42" concrete cylinder water transmission main (PN 233-1987) and a 12" cement asbestos water distribution main (PN 115-1974) in Silverbell Road. Tucson Water's Distribution Design Section will need to review and approve the plans for installing this drainage structure. 4. The provided site plan shows symbols and lines that could be new water mains Silverbell Road and new water service lines and water meters located on the west side of the property. If that is what those symbols and lines represent, those features will need to be reviewed and approved by Tucson Water's Distribution Design Section, as well. 5. The provided site plan also shows that grading will need to be done over an existing 8" PVC water main on the site (PN 150-2007). Care will need to be taken during this grading to ensure that adequate cover is maintained over this existing water main. 6. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 07/08/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0138 1) Confirm the number of peak hour trips expected by this expansion. If the number exceeds 100 then a traffic impact analysis may be required per City of Tucson Access Management Guidelines John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |