Plan Number: T21PRE0136
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0136
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2021 AWARNER1 LANDSCAPE REVIEW Completed FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: Costco parking expansion
T21PRE0136

TRANSMITTAL DATE: July 1, 2021

This project is subject to The Bridges PAD-15 landscape requirements.

UDC Article 7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening


If you have any questions about this transmittal, Contact me at my email anne.warner@tucsonaz.gov
06/28/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 210-230 pm - T21PRE0136 - 1650 E Tucson Mktpl - Site Costco, expand parking lot

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. There is an existing 12-inch ductile iron public water main and an 8-inch PVC water main stub constructed under Plan No 001-2010 in the northwest corner of the proposed new parking area. Care will need to be taken when working in this area to avoid damaging these public water mains.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
06/30/2021 MROSS2 COT NON-DSD FIRE Completed None



Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
06/30/2021 LSHAMIS1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Planner, MBA

PROJECT: Thursday Pre-submittal meeting - T21PRE0136
Address: 1650 E Tucson Marketplace
Parcel(s): 132130730
Zoning: PAD-15
Existing Use: Commercial Shopping Center Development
Proposed Use: Parking lot expansion

TRANSMITTAL DATE: June 30, 2021

COMMENTS:
1.Development must comply with the Administrative Manual Section 2-06 - Development Package.
2.The proposed use is large retail establishment is permitted in PAD-15, Sub-Area A. Subject to C.2.2.C.2 of the PAD document.
3.Demonstrate compliance with PAD-15. https://www.tucsonaz.gov/files/pdsd/plans/Bridges_PAD_Amendment-MayorCouncil-May_2018.pdf
4.The parking calculation per PAD-15 is a minimum of 4.5 spaces for each 1,000 square feet of Gross Floor Area (GFA).
5.Update the number of ADA accessible vehicle parking spaces required based on the proposed number of parking spaces - the parking calculation is 2% of the number of proposed parking spaces.
6. The proposed lot split will require a separate application and review - https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
06/30/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0136
1. Site is in a critical basin. Provide critical basin detention and first-flush retention.
2. Maximize water harvesting.
Loren Makus, EIT
loren.makus@tucsonaz.gov
07/01/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed No adverse comments