Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2021 AWARNER1 LANDSCAPE REVIEW Completed FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: 345 E Teton Rd
T21PRE0134

TRANSMITTAL DATE: July 1, 2021


UDC Article 7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening

If you have any questions about this transmittal, Contact me by email at anne.warner@tucsonaz.gov
06/28/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130-150 pm - T21PRE0134 - 345 E TETON RD - Block Plat Split 1 lot into 4 lots

1. Tucson Water's New Area Development unit has no objections to this parcel being split, but finds the proposed lot configurations unacceptable, as Lots A & B would not have direct access to the public water main in Teton Rd.

2. Per Tucson Water's Remote Meter policy, either each of the proposed new needs to have a minimum of 15' of frontage on Teton Rd, or public water main extensions will need to be constructed to serve Lots A & B in dedicated public water-line easements or public rights or way

3. The easternmost 24' wide access easements could be made part of Lot A, and the other 24' wide access easement to the west could be made part of Lot B to comply with Tucson Water's Remote Meter policy.

4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
06/30/2021 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
06/30/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0134
1. Site is greater than 1 acre. Compliance with drainage manual is required. Balanced basin detention and first flush retention are required.
2. A four-plex is commercial. Site with a triplex requires commercial development standards.
3. Lot is within a platted subdivision, Golden Dawn Farms, and has been previously split. Any lot division will require a subdivision. A tentative plat is required since the street is not fully developed.
4. Show that existing development will not become non-conforming by this development.
5. Entrance PAAL must have sidewalk to Teton Road.
6. Construction may be in phases. If you want to subdivide in phases, additional fees will be required at each stage.
7. Address how solid waste will be collected. Collection must meet the requirements of Technical Standard 8-01.
Loren Makus, EIT
loren.makus@tucsonaz.gov
07/01/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0134

1) If a subdivision is undertaken a tentative plat will be required in part to fully develop Teton St, including but not limited to new driveways, sidewalk and a method or means of controlling drainage, such as new vertical curb. A Private Improvement agreement would be required for this Right of Way improvements
2) Standard detailing requirements will apply

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
07/01/2021 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T21PRE0134

TRANSMITTAL DATE: 6/30/21



DUE DATE: 7/01/21





1.COMMENT: Include existing and proposed square footage for each lot. Minimum lot size for R-2 Lot is 5,000sf UDC 6.3-2.A



2.COMMENT: Include The boundaries of the original parcel or lot prior to the land split with distance and bearings labeled. Include The proposed lots with distance and bearings labeled



3.COMMENT: Provide drawings of all the existing structures on the plans with accurate location and dimensions. Provide setback dimensions from existing structures to the new lot lines for both the south and the west. All future and existing structures must comply with setback requirements.



If any structures are to be removed mark them as such



4.COMMENT: Provide lot coverage calculations for Lot A to ensure it is less than maximum limit for R-2 Zone UDC 6.3-2.A (SF:70% MF:75%)



5.COMMENT: Clarify if access easement on the east of the property also provides access to Lot A



6.COMMENT: Parking dimensions are not required on the plans

7.COMMENT: Ensure Access lanes are atleast 20' wide.

If you have any questions about this transmittal, Contact Iman Monshizadeh by email Iman.Monshizadeh@tucsonaz.gov or contact Elisa Hamblin, at Elisa.Hamblin@tucsonaz.gov