Plan Number: T21PRE0124
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0124
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/27/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/NPPO Review
PROJECT: 6335 E Tanque Verde Rd, Self Storage
T21PRE0124

TRANSMITTAL DATE: June 3, 2021


UDC Article 7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.


UDC Article 7.7. Native Plant Preservation
An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) is required prior to Grading Plan approval.


UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening


If you have any questions about this transmittal, Contact Anne Warner at (520) 837-4969 or by email anne.warner@tucsonaz.gov
06/02/2021 MROSS2 COT NON-DSD FIRE Completed 1. Automatic fire sprinkler system will be required.
2. Fire alarm system will be required.
3. Aerial Fire Apparatus Access Roads
D105.1 Where required.
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided.
D105.2 Width.
Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building.
One or more of the required access routes meeting this condition shall be located not less than 15 feet and not greater than 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official.
4. Emergency responder radio coverage will need to be tested.
510.1 Emergency responder radio coverage in new buildings.
New buildings shall have approved radio coverage for emergency responders within the building based on the existing coverage levels of the public safety communication systems utilized by the jurisdiction, measured at the exterior of the building.

Michael Ross
520-837-7082
06/02/2021 LSHAMIS1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Planner, MBA

PROJECT: Thursday Pre-submittal meeting – T21PRE0124
Address: 6335 E Tanque Verde Rd
Parcel(s): 13316030C
Zoning: C-2
Existing Use: Vacant
Proposed Use: Personal Storage - Wilmot Tower’s Self Storage

TRANSMITTAL DATE:

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposed use, Personal Storage, is permitted in the C-2 zone. Use specific standards 4.9.10.C.3 & .6.
a. 4.9.10.C.3 – All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material
b. 4.9.10.C.6 – The facility’s exterior façade visible from adjoining residential properties or street frontage shall be earth tone in color and/or masonry, stucco, or similar materials.
3. 40’ is the maximum height permitted in the C-2 zone.
4. The perimeter yard setback requirements are 0’. The street yard setback requirement is 21’ or the height of the adjacent wall, the greater applies, measured from the back of the existing curb or future curb location.
5. The vehicular parking space requirement is 1 space per 4,000 sq ft of GFA, if the storage units do not have direct vehicular access; the required number of vehicular parking spaces is 30, 2 of which must be ADA accessible.
6. Clarify which vehicular parking spaces are intended to serve the proposed use.
7. A cross access agreement must be established with for any other parcel being used as access to the subject parcel (parcels to the North and South). Additionally, It appears that the parking spaces to the North are a part of the subject parcel however maneuvering in/out of the spaces occurs on the parcel to the North.
8. The requirement for short-term bicycle parking spaces is 1 space per 5,000 sq ft GFA, 24 short-term bicycle spaces are required; and for long-term bicycle parking is 1 space per 12,000 sq ft GFA, 8 long-term bicycle spaces are required. See design criteria in the UDC, Section 7.4.9.
9. Two Type A loading areas are required. See design criteria in the UDC, Section 7.5.4.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
06/02/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 210 - 230 pm - T21PRE0124 - 6335 E TANQUE VERDE RD - Site Wilmot Towers Self-Storage

1. Tucson Water's New Area Development unit has no objections to the proposed development.

2. There is an existing 8" cement asbestos water main in Wilmot Road (PN 015-1962) that can serve the proposed development.

3. After a water fixture unit count has been conducted for the project using the 2018 International Plumbing Code, and the numerical fire flow requirements have been established by the local fire authority, please contact Tucson Water's New Services section by sending an e-mail to TW_COMMON@tucsonaz.gov to discuss:
a. The number and type of water service lines, water meters, and meter sizes, necessary to serve this development.
b. The advantages and disadvantages of installing the necessary water service lines and water meters via Tucson Water's Job Order Contract (JOC) process.

4. Please note that hydraulic modeling may need to be performed to verify which potential points of connection have the capacity necessary to provide the required fire flow to the proposed development. If so, this will be arranged by Tucson Water's New Services section.

5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:
Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
06/02/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. As part of the Development Package show joint use access/parking agreements with neighboring parcels.
2. Site is within a balanced basin. Detention and 5-year threshold retention is required.
3. Retention and detention must comply with new manual that took effect June 1. https://www.tucsonaz.gov/pdsd/codes-plans
4. Show a complete pedestrian circulation path.
5. Maximize water harvesting.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
06/03/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0124

1) The existing driveway and entrance off of N Wilmot Rd will need to show that the largest expected vehicle can enter without causing an obstruction or interference to existing onsite traffic circulation. Maneuvering radii will need to be shown. The driveway entrance may need to be reconstructed. or re-positioned. Reference City of Tucson Access Management Guidelines section 5.12

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov