Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T21PRE0100
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0100
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2021 MROSS2 COT NON-DSD FIRE Completed 1. Kitchen hood suppression systems require a deferred submittal through TFD
2. CO2 systems in excess of 100 lbs require a leak detection and notification system per 2018 IFC section 5307


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
05/06/2021 LOREN MAKUS ENGINEERING REVIEW Completed 1. Show adequate throat length for the entry from Broadway. Transportation Access Management Guidelines section 5.11.
2. Provide 25-foot curb returns for driveway from Broadway.
3. Show continuous pedestrian connection through the site. Change the location of the pedestrian crossing through the drive-through lanes.
05/12/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T21PRE0100 - 2744 E BROADWAY BL - SiteGrading Freddy's restaurant

1. Tucson Water has no objections to the proposed development.

2. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
05/13/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0100

1) Plans do not match the currently under construction Broadway Road Project. For copies of the line work contact the Design Consultant HDR @ brent.kirkman@hdrinc.com

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
05/13/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting – T21PRE0100
Address: 2744 E BROADWAY BL
Parcel(s): 12902087A
Zoning: C-1
Existing Use: Vacant
Proposed Use: Food Service

TRANSMITTAL DATE: 05/12/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Sunshine Mile UOD is in process, it is an opt in Overlay that is more restrictive for drive-throughs.
3. The use per the UDC is Food Service and is subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. Provide the use and Use Specific Standard code callouts as a general note on the Development Package.
4. Per Use Specific Standard 4.9.13.O.1.a, Commercial Services and Retail Trade Uses are limited to one drive-through lane. Two lanes have been proposed on the provided site plan, revise to one lane on Development Package submittal.
5. Broadway Blvd is a Major Street and Route and is proposed to be widened to 150 ft. All plans must reflect the future ROW dimensions.
6. The setback requirement on Broadway Blvd. is 21’ measure from the back of the Future Curb location.
7. Pedestrian access is required to connect to all adjacent ROWs.
8. Sidewalks or crosswalks cannot cross any type of stacking areas for drive-through lanes.
9. Short-term bicycle parking will be required at 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces.
10. Long-term bicycle parking will be required at 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces
11. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
05/13/2021 AWARNER1 LANDSCAPE REVIEW Passed