Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0100
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 1. Kitchen hood suppression systems require a deferred submittal through TFD 2. CO2 systems in excess of 100 lbs require a leak detection and notification system per 2018 IFC section 5307 Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 05/06/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Show adequate throat length for the entry from Broadway. Transportation Access Management Guidelines section 5.11. 2. Provide 25-foot curb returns for driveway from Broadway. 3. Show continuous pedestrian connection through the site. Change the location of the pedestrian crossing through the drive-through lanes. |
| 05/12/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T21PRE0100 - 2744 E BROADWAY BL - SiteGrading Freddy's restaurant 1. Tucson Water has no objections to the proposed development. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 05/13/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0100 1) Plans do not match the currently under construction Broadway Road Project. For copies of the line work contact the Design Consultant HDR @ brent.kirkman@hdrinc.com John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 05/13/2021 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0100 Address: 2744 E BROADWAY BL Parcel(s): 12902087A Zoning: C-1 Existing Use: Vacant Proposed Use: Food Service TRANSMITTAL DATE: 05/12/2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Sunshine Mile UOD is in process, it is an opt in Overlay that is more restrictive for drive-throughs. 3. The use per the UDC is Food Service and is subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. Provide the use and Use Specific Standard code callouts as a general note on the Development Package. 4. Per Use Specific Standard 4.9.13.O.1.a, Commercial Services and Retail Trade Uses are limited to one drive-through lane. Two lanes have been proposed on the provided site plan, revise to one lane on Development Package submittal. 5. Broadway Blvd is a Major Street and Route and is proposed to be widened to 150 ft. All plans must reflect the future ROW dimensions. 6. The setback requirement on Broadway Blvd. is 21’ measure from the back of the Future Curb location. 7. Pedestrian access is required to connect to all adjacent ROWs. 8. Sidewalks or crosswalks cannot cross any type of stacking areas for drive-through lanes. 9. Short-term bicycle parking will be required at 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces. 10. Long-term bicycle parking will be required at 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces 11. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |
| 05/13/2021 | AWARNER1 | LANDSCAPE | REVIEW | Passed |