Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0099
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 05/05/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T21PRE0099 - 3805 E BROADWAY BL - Site Parking lot and refuse collection 1. Tucson Water has no objections to the proposed development. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St., P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 05/06/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0099 1) Refer to City of Tucson Access Management guidelines section 5.11. The location of the one parking space to the west and the 5 on the east side of the Broadway driveway entrance create a conflict with inbound traffic. Update plans as needed John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 05/06/2021 | AWARNER1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis; MBA, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0099 Address: 3805 E Broadway Bl Parcel(s): 12517032A Zoning: C-1 Existing Use: Bank Proposed Use: Administrative and professional office TRANSMITTAL DATE: May 6, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposed use is administrative and professional office, or other similar commercial use with similar intensity by parking calculation, which is permitted in the C-1 zone. Use specific standard 4.9.13.O is applicable for administrative and professional office use. a. Follow up comment pertaining to the use-specific standards - address the plan for the existing drive-through. 3. Correct the parking calculation - The parking requirement is 1 vehicular parking space per 300 GFA of building. Currently the site plan says 25 are required and 26 are provided, but the site only demonstrates 25 parking space. Update the general note to read 26 vehicular parking spaces are required, 2 of which must be ADA compliant and one being van accessible. 4. An ADA accessible pedestrian circulation path is required to connect all areas of development on the site and to the adjacent street (Technical Standards Manual, Section 7-01.3.0) – add an ADA compliant, marked pedestrian circulation path (minimum 4’) connecting the building to the refuge area. 5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
| 05/06/2021 | AWARNER1 | LANDSCAPE | REVIEW | Needs Review | |
| 05/06/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. The waste stream calculations (office or small retail use) shows about 125 gallons per week. Roll cans should be acceptable with service from El Camino Del Norte. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |