Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0088
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 04/27/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 1. Kitchen hood suppression systems require a separate permit through the Tucson Fire Department. 2. If the occupant load is over 100 an automatic fire sprinkler system is required. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 04/28/2021 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0088 Address: 1800 W VALENCIA RD Parcel(s): 137-33-909A Zoning: C-2 Proposed Use: Food Service TRANSMITTAL DATE: 4/29/2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package 2. This site was subdivided in 2001 and has not been split since. A lot split can be recorded without need to go through the subdivision process. 3. On the Development Package (DP) list the use and code call out of Use Specific Standards as a general note. (i.e. The proposed used is Food Service and is subject to Use Specific Standards 4.9.4.M.1 and 4.9.13.P 4. Activities may be conducted outdoors. Loudspeakers or music, live or recorded, shall not be permitted within 600 feet of a residentially zoned property 5. The max height in this zone is 40’ 6. The UDC requires 1 parking space per 100 sq. ft. GFA and outdoor seating areas. Provide a lot coverage calculation with the area of the seating areas on the DP. 7. 4 vehicle stacking spaces are required Food Service where there are separate points of service for ordering and pick-up. 8. Short term bicycle parking spaces are required at 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces. 9. Long term bicycle parking spaces are required at 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. 10. No loading spaces are required for food service with less that 5,000 sf of GFA. 11. Pedestrian access will be required to connect to the adjacent ROW, W Valencia Rd. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov |
| 04/28/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T21PRE0088 - 1800 W VALENCIA RD - SiteGradingSwppp Raising Cane's Restaurant 1. The existing 6" water main constructed under PN 241-2000 (in the parking lot west of the proposed Raisin' Canes' restaurant) may be tapped to supply water to the proposed development. 2. The existing 42" concrete cylinder water main constructed under PN 032-1967 in Valencia Road may not be tapped 3. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 04/29/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0088 1) No adverse comments. Assuming this project does not result in a 25% site expansion or more John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 04/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show a complete pedestrian circulation path 2. See Technical Standards Manual section 8-01.5.2 for Trash Enclosure Specifications. Canopies over the enclosure are not required. 3. Maximize water harvesting in new landscape areas. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |