Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Active
Review Details: PREAPPLICATION MEETING
Plan Number - T21PRE0087
Review Name: PREAPPLICATION MEETING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/06/2021 | JOHN BEALL | M&C Public Hearing 4 Plan Amendment | Set M&C Public Hearing Date | Active | |
| 04/13/2021 | BILLIE LEE | COMMENTS | COMMENTS | Active | |
| 04/13/2021 | ELISA HAMBLIN | ZONING | REVIEW | Completed | Rezoning Pre-Submittal Transmittal FROM: Elisa Hamblin, AICP PDSD Zoning Review PROJECT: Rezoning Pre-submittal meeting T21PRE0087 Address: 10125 E Corte Vista La Mariposa and others Parcel(s): 133-03-3960, 133-03-3970, 133-03-3980, 133-03-3990, 133-03-4000, 133-03-4010, 133-03-4020, 133-03-304C Existing Zoning: S-R and O-3 Proposed Zoning: R-2 Existing Use: Vacant Proposed Use: Multifamily Development TRANSMITTAL DATE: April 13, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Development standards: 15 units/acre, 75% lot coverage, 25 ft height max 3. Proposed use and use-specific standards: Multifamily development, 4.9.7.B.6, .9, & .10 4. Perimeter yard setbacks: 10 ft or ¾ height, whichever is greater 5. Applicable overlays: Environmental Resource Zone (ERZ) 6. Major Streets and Routes Plan: Houghton – Arterial Scenic – 200 ft 7. Applicable street setbacks: 3 times height (due to scenic standards) 8. Parking requirements: 308 spaces 9. Bike parking requirements: 33 short-term, 164 long-term 10. Landscape requirements can be discussed further with Andy Connor at andrew.connor@tucsonaz.gov. 11. Additional comments: recommend discussing floodplain and impact to potential development impacts 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at elisa.hamblin@tucsonaz.gov. |
| 04/13/2021 | ANY | ELECTRICAL ENGINEERING | REVIEW | Active | |
| 04/29/2021 | MROSS2 | FIRE | REVIEW | Completed | Fire hydrants are required to be a maximum of 400' or 600' if buildings are sprinklered, from any exterior portion of all buildings. Sprinklers are required for multi family residential housing. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |