Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0086
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. Street Landcape Borders Location Must be located entirely on , except that, if approved by the City Engineer or designee, up to five feet of the required ten foot width may be placed within the area or within the on MS&R . |
| 04/27/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | 1. An automatic fire sprinkler system will be required. per 2018 IFC 903.2.8 Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 04/28/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 300 - 330 pm - T21PRE0086 - 701 E ELM ST - Site 1st Avenue Elm Homes 1. Tucson Water has no objections to the proposed development. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 04/29/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | T21PRE0086 1) Approval to use a portion of the right of way for the required landscaped buffer will be required. Contact Landscape Architect David Marhefka >> david.marhefka@tucsonaz.gov << John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov |
| 04/29/2021 | AWARNER1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Anne Warner, RLA, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0086 Address: 701 E Elm St Parcel: 123-15-0150 Zoning: R-2 Existing Use: Residential Proposed Use: Multi-family TRANSMITTAL DATE: April 29, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use is allowed in the R-2 zone, add as a General Note on the Development Package; allowed under the Residential Land Use Group, Multi-family UDC Table 4.8.2, subject to Use Specific Standards 4.9.7.B.6, .9 & .10. 3. Add Dimensional Standards for the R-2 zone in accordance with Table 6.3-2A, including lot coverage calculations, 75%, and max. building height (25’). Perimeter yard requirements are 10' from the property line or 3/4 the height of the exterior building wall, whichever is greatest. Street setback requirements are found in UDC 6.4.5.C-1. 4. Provide required vehicular and bicycle parking calculations using UDC 7.4.3.F requirements and Table 7.4.4.1, and for bicycle, Article 7.4.8.B. 5. Both the DP and building plans can be submitted at any time, however the DP must be approved prior to the building plans approval, so it is prudent to wait for the first round of DP comments before submitting building plans. 6. Include dedication information on all easements traversing the property, as well as recording information for the streets. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at anne.warner@tucsonaz.gov or (520) 837-4969. |
| 04/29/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. City code requires centralized solid waste storage and collection for multifamily complexes. Provide enclosure and show access route for solid waste vehicle. 2. Provide waste stream calculation. In addition provide a minimum of 45 gallons capacity per unit. 3. Show pedestrian circulation path out to 1st Ave. 4. The minimum two-way aisle width for a PAAL accessing 90-degree parking is 24' per UDC table 7.4.6-1. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |