Plan Number: T21PRE0077
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0077
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/31/2021 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
04/08/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0077
1. Provide approved surface for vehicle use areas.
2. City code requires centralized solid waste storage and collection for multifamily complexes. Provide enclosure and show access route for solid waste vehicle.
3. Provide waste stream calculation. In addition provide a minimum of 45 gallons per unit of capacity per unit.
4. Maximize water harvesting.
04/14/2021 MROSS2 COT NON-DSD FIRE Completed Any new R occupancies are required to be equiped with an automatic fire sprinkler.
Any new structure is required to be within 400' of a fire hydrant, that is increased to 600' if the building is sprinklered.

Fire apparatus access roads shall be capable of supporting 75,000 lbs.

Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
04/21/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130-200 pm - T21PRE0077 - 3428 E PRESIDIO RD - Site Duplex addition

1. Each of the existing duplexes and apartments on the site are served by individual water meters, and I assume you will want to continue that practice with the new units.
2. Please contact Tucson Water's New Services section by sending an e-mail to TW_COMMON@tucsonaz.gov to determine what difficulties, if any, will be encountered installing additional new water meters for the proposed development.
3. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
04/21/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0077

1) Minimum 5' wide sidewalk along property frontage along with a new PAG detail 206 Apron will be required

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
04/22/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T21PRE0077
Address: 3428 E PRESIDIO RD
Parcel(s): 11-05-153C, 111-05-153D, 111-05-153E
Zoning: R-2
Existing Use: Residential: Single-Family/Duplex
Proposed Use: Multifamily

TRANSMITTAL DATE: 04/22/2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. This site is in the R-2 zone which allows for 15 units/acre
3. A lot combo will be required for this development. Submit application for a lot combination to county, accessor confirmation of submitted lot combination form must be submitted prior to the issuance of the development package.
4. You will need to submit for a Development Package (DP). A DP will be required to be issued prior to issuance of any building permits, however building permits can be submitted as risk prior to the DP's issuance.
5. 19 parking spaces will be required.
6. 2 long-term and 2 short-term bicycle parking spaces will be required.
7. Pedestrian connection will be required to the adjacent ROW
8. The use per the UDC will be multifamily and is subject to use specific standards 4.9.7.B.6, .9, & .10
a. .6: No manufactured homes
b. .9: Non-conforming group dwellings
c. .10: No group dwellings (5 or more unrelated people)
9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.