Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0072
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/31/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 04/06/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 04/07/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show pedestrian circulation path to trash enclosure. 2. Show pedestrian circulation path to shopping plaza and E Wetmore Rd. 3. Maximize water harvesting. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 04/07/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 300 - 330 pm - T21PRE0072 - 593 E WETMORE RD - Site Quick Oil Change 1. There is an existing 8" cement asbestos water main in Wetmore Rd (PN 068-1983) that can serve this proposed development. 2. When you are ready to obtain water service for this proposed development, please contact Tucson Water's New Services section by sending an e-mail to TW_COMMON@tucsonaz.gov to discuss: a. Potential points of connection to Tucson Water's existing water distribution system. b. The number of water service lines, water meters, and meter sizes, necessary to serve this development. c. The advantages and disadvantages of installing the necessary water meters via Tucson Water's Job Order Contract (JOC) process. 3. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 04/08/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | no comments at this time |
| 04/08/2021 | AWARNER1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Anne Warner, RLA, Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0072 Address: 593 E Wetmore Rd. Parcel: 105-10-243B Zoning: C-3 Existing Use: Parking lot for shopping center Proposed Use: Oil Change, Commercial Use TRANSMITTAL DATE: April 8, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use is allowed in C-3 zone, commercial land use, minor service and repair, no use specific standards, with max. bldg. height – 75’ 3. Major Streets & Routes setback is 21’ or the height of the building whichever is greater, measured from future back of curb, not existing curb. Wetmore Road’s existing right of way is 85’, future is 120’. 4. Required perimeter yard setbacks are 0’. 5. Parking requirements are 1/300 GFA, Reference previous development plan for the shopping center for existing number of parking spaces and other calculations. Show dimensions on ADA and required parking spaces. 6. Long term bicycle parking is not required, 2 short term bicycle spaces are required. 7. A Minor subdivision or block plat will be required, reference requirements in the UDC Administration Manual Section 2-07. 8. Aerial photography under the site plan on the development package (DP) submittal is not necessary. 9. Both the DP and building plans can be submitted at any time, however the DP must be issued prior to the building plans. 10. Pedestrian connection needs to be provided to the sidewalk along Wetmore Road. 11. Trash collection is infringing on the stacking The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at anne.warner@tucsonaz.gov or (520) 837-4969. |