Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0070
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 04/06/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | -A defered submittal and separate permit is required for kitchen hood extinguishing systems through TFD -CO2 systems in excess of 100lbs are required to have a leak detection system, (permit is required through TFD) -All portions of the building are required to be within 400' of a fire hydrant, 600' if the building is equipped with a fire sprinkler system. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 04/07/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show the solid waste collection maneuverability with dimensions to ensure adequate space to pull in and back out. 2. Show pedestrian circulation path to trash enclosure. 3. Show pedestrian refuge between shared access and drive and the building to the southeast. 4. Get with DTM to resolve driveway spacing between site and adjacent property to the southeast. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 04/07/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T21PRE0070 - 6565 E GRANT RD - Site Popeye's Louisiana Kitchen 1. There is an existing 4" cement asbestos water main on the north side of Grant Rd. (PN3062) that can supply potable water to the site, but please be aware that this water main is too small to provide flow to a new fire hydrant. 2. If a new fire hydrant must be constructed to serve the proposed development, please have the fire department determine the required fire flow for the type of construction, and then contact me to discuss possible options. The construction of several hundred linear feet of new 8" public water main is likely to be involved. 3. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 04/08/2021 | JVWINKL1 | COT NON-DSD | TRAFFIC | Completed | no comments at this time |
| 04/08/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0070 Address: 6565 E. Grant Road, Parcel: 13316020X Zoning: C-1 Existing Use: Vacant Proposed Use: Commercial-Food Service TRANSMITTAL DATE: April 8, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The applicant is proposing a fast-food restaurant and a likely demolition of the existing structure. The proposed use is Commercial-Food Service. Food service is permitted in the C-1 zone with the following use-specific standards: a. 4.9.4.M.1 b. 4.9.4.M.5 c. 4.9.13.O 3. If the existing structure is more than 50 years old Historic review is required for demolition. 4. Parking is calculated at 1 space per 100 square feet. 5. Setbacks for a non-residential use adjacent to a residential zone in the C-1 are 1 ½ the height of the structure. Show all setbacks on the Development Package. 6. Grant is a major street. All street setbacks will be measured from back of future curb. 7. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Ensure pedestrian circulation standards are met. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |