Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0066
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/23/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Buildings 10,000 Square Feet or Less On where the of the existing (s) is 10,000 square feet or less, expansions in square footage of land area, , , or as follows. a. If the expansion is less than 50%, the standards of this section apply only to the proposed expansion. Existing on the is subject to the zoning standards in effect at the time the existing received zoning approval. b. If the expansion is 50% or greater or if expansions as of February 15, 1991, cumulatively result in a 50% or greater expansion in land area, , , or , the standards of this section apply to the entire . |
| 03/25/2021 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Project does not have frontage to ROW. No comments at this time |
| 03/25/2021 | JPEELDA1 | COT NON-DSD | FIRE | Completed | New building shows 9,120 sq feet you will need to provide TFD the type of construction so that we can confirm the fire flow requirements. Letter shall be provided from Tucson Water to confirm fire flow is met and or you shall install fire sprinklers. |
| 03/31/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T21PRE0066 1. Site is within a City of Tucson floodplain. Floodplain use permit is required. 2. Hydrology report is required to determine floodplain parameters such as base flood elevation and possible adverse impact to adjacent properties. 3. Maximize water harvesting. |
| 04/01/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T21PRE0066 - 1401 W GLENN ST - Site Granite SpecialistsStockett Tile 1. There is an existing 6" cement asbestos water main (WO 6872) on the west side of the property in the Flowing Wells spur that can serve the proposed new building. 2. Should a new water meter be necessary to serve the new building, plplease contact Tucson Water's New Services section by sending an e-mail to TW_COMMON@tucsonaz.gov to discuss: o Potential points of connection to Tucson Water's existing water distribution system. Please note that hydraulic modeling may need to be performed to verify which potential points of connection have the capacity necessary to serve the proposed development. o The number of water service lines, water meters, and meter sizes, necessary to serve this development. o The advantages and disadvantages of installing the necessary water meters via Tucson Water's Job Order Contract (JOC) process. 3. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
| 04/01/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0066 Address: 1401 W Glenn St., Parcel: 10704002 Zoning: I-1 Existing Use: Retail-General Merchandise Proposed Use: Retail-General Merchandise TRANSMITTAL DATE: March 31, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The applicant is proposing a second building on an existing parcel. The proposed uses for the building are General Merchandise Sales, Commercial Storage, and General Manufacturing. Each of the proposed uses is permitted in the I-1 zone with the following use specific standards: a. General Merchandise Sales: 4.9.13.Q b. Commercial Storage: 4.9.10.A and 4.9.13.Q c. General Manufacturing: 4.9.5.C2, .6, .7 & .8 and 4.9.13.Q 3. The maximum height of a building in the I-1 is 75'. There are no setback minimums for a nonresidential use to a nonresidential zone. 4. Parking will be calculated at 1 space per 300 square feet unless the applicant provides more information about the use of the space. It appears the applicant is proposing 20,370 total square feet of building, unless specified otherwise. The site would require 68 parking spaces. Commercial Storage parking is calculated at 1 space per 5,000 square feet. Industrial-General Manufacturing parking is calculated at 1 space per 1,000 square feet. 5. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Ensure pedestrian circulation standards are met. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
| 04/05/2021 | SBEASLE1 | COT NON-DSD | TRAFFIC | Needs Review | Project does not have frontage to ROW. No comments at this time |