Plan Number: T21PRE0062
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0062
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/30/2021 MROSS2 COT NON-DSD FIRE Completed If the houses exceed 3,600 sq feet under roof including the porches, garages and other items a letter will need to be submitted with the plans showing that they meet the required fire flow from Tucson Water. Fire flow numbers can be found with TFD. Also, the furthest part of the house from a hydrant cannot be longer than 600' as the hose lays and that shall be submitted with the drawings as well. If you have any questions please call or email me.

Thank you,
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
12/07/2021 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T21PRE0062
Address: 941 E Coventry Pl
Parcel(s): 13822013T
Zoning: R-1
Existing Use: SFR
Proposed Use: SFR Subdivision

TRANSMITTAL DATE:

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. It does not appear that lot 3 and 4 have direct access to East Coventry Place.
3. The minimum lot size in the R-1 zone is 7,000 sf, nearly all of the lots do not meet this size requirement.
4. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
12/07/2021 JVWINKL1 COT NON-DSD TRAFFIC Completed T21PRE0062

1) Curb and Sidewalk will be required along W Coventy Pl and W Teton St
2) Remaining half ROW along W Teton St will require completion

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
12/07/2021 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Minor Subdivision
ACTIVITY NO. T21PRE0062
ADDRESS/PARCEL: 941 W Coventry Pl
ZONING: R-1


7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survived.

An approved Native Plant Preservation Plan Sections 7.7.4 is required or a request for an exception from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 is required prior to Grading Plan approval.

Water harvesting - Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with rainwater harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
12/09/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Site is in a critical basin. Critical basin detention and first flush retention are required.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
12/09/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 1:30 - 2:00 pm - T21PRE0062 (2nd submittal) - 941 W COVENTRY PL - Minor Subdivision

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. There are existing water mains in W Coventry Place and W. Teton Street that can serve the six proposed lots.

3. Each of the six proposed lots must have its own water service line and water meter.

4. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov