Plan Number: T21PRE0060
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0060
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2021 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
03/22/2021 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply.
03/22/2021 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed T21PRE0060
1) Please contact City of Tucson Real Estate for discussion of vacation of existing Right of Way. Existing units access will need to be maintained through appropriate easements
2) Driveway connection to Winstel will need to meet PAG standard detail 206
3) Access path requires Fire and ES approval


John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
03/23/2021 MROSS2 COT NON-DSD FIRE Completed Fire department access roads with a dead-end in excess of 150' shall be provided with a turn around per IFC 2018 Appendix D.
The fire apparatus access road shall extend to within 150' of all portions of all buildings.
A fire sprinkler system will be required.


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov
03/24/2021 NMARTEL1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Nicholas Martell, Planner
PROJECT: Thursday Pre-submittal meeting - T21PRE0060
Address: No Address , Parcel: 11106016B
Zoning: R-3
Existing Use: Vacant
Proposed Use: Multifamily Development
TRANSMITTAL DATE: March 25, 2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The applicant is proposing multifamily residential in an R-3 zone. Multi-family residential is permitted in the R-3 zone at 36 units per acre. The proposed four units are permissible on a 6,975 sq ft. lot.
3. More information regarding building height is needed to determine setbacks. The plans show a 6' setback to the south; setbacks are measured at 10' or ¾ the height of the building for a nonresidential use in the R-3.
4. Parking will be calculated per bedroom. More information is needed to determine parking spot requirements. (Table 7.4.4-1)
5. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Ensure pedestrian circulation standards are met. Vehicle maneuverability must occur on-site. Pedestrian access to the street is required.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov
03/25/2021 SBLOOD1 ENGINEERING REVIEW Completed 1. Show pedestrian circulation path to N Winstel Bl.
2. Show waste stream calculations and any required trash enclosures.
3. Show the solid waste collection maneuverability with dimensions to ensure adequate space to pull in and back out.
4. Contact ES for approval of site and solid waste disposal plans

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
03/26/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change 200 - 230 pm - T21PRE0060 - 2928 N WINSTEL BL - Site Winstel two duplexes

1. This property does not front any existing water main.

2. To bring water to this property and comply with Tucson Water's remote meter policy, the Applicant will need to construct approximately 200' of 4" water main from the 6" cement asbestos water main on the west side of Winstel Blvd (PN 002-1964) through the public right of way on the north side of the property.

3. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106