Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T21PRE0043
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T21PRE0043
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
03/09/2021 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
03/09/2021 ANY ELECTRICAL ENGINEERING REVIEW Active
03/10/2021 ELISA HAMBLIN ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Elisa Hamblin, AICP; Principal Planner
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T21PRE0043
Address: 6401 S Midvale Park Rd
Parcel(s): 13727991E
Existing Zoning: C-1
Proposed Zoning: C-2
Existing Use: Vacant
Proposed Use: Personal Storage

TRANSMITTAL DATE: March 10, 2021

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Development standards: 40 ft building height
3. Proposed use and use-specific standards: Personal Storage, 4.9.10.C.3 & .6 (see below)
a. All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material.
b. The facility’s exterior facade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials.
4. Perimeter yard setbacks: 0 ft
5. Applicable overlays: Tucson Airport – Avigation Easement and Disclosure Area
6. Major Streets and Routes Plan: Midvale Park Rd – Arterial – 150 ft
7. Applicable street setbacks: 21 ft or building wall height as measured from back of future curb on Midvale Park Rd, as measured from outside edge of adjacent travel lane on Commerce Ct
8. Parking requirements: 1 space per 4,000 sq. ft. GFA, if storage units do not have direct vehicular access, and a minimum of 2 spaces for any associated office, total of 28 required for this proposal
9. Bike parking requirements: 2 spaces short-term
10. Loading space requirements: 2 Type A spaces required
11. Landscape requirements can be discussed further with Andy Connor at andrew.connor@tucsonaz.gov or 520-837-4950.
12. Additional comments: Recommend attending CDRC Pre-Submittal meeting to get feedback from Fire, Engineering and other reviewers.
13. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at elisa.hamblin@tucsonaz.gov.
03/10/2021 ZELIN CANCHOLA COMMENTS COMMENTS Completed No adverse comments. Standard requirement will apply during development process.
03/17/2021 MROSS2 FIRE REVIEW Completed -Fire sprinklers will be required
-A fire alarm system will be required
-Any new building is required to have all portions of the exterior within 600' of a fire hydrant.
-Fire flow requirements need to be met, will depend on type of construction used.
-Vehicle pass through must meet fire department access requirements. minimum height of 15'.
-Turns on fire department access roads shall have a minimum raius of 18'.


Michael Ross
520-837-7082
Michael.Ross2@tucsonaz.gov