| 02/17/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 02/22/2021 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirements will apply. |
| 02/23/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | The Market building is listed as 30' in height. Buildings that exceed 30 feet to the highest roof surface require an approved arial fire apparatus access road. Michael Ross 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 02/24/2021 | NMARTEL1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Planner PROJECT: Thursday Pre-submittal meeting - T21PRE0033 Address: 320 S Wilmot Parcel(s): 128-01-011B, 128-02-038A Zoning: P, C-1 Existing Use: Retail Proposed Use: Food Service, General Merchandise TRANSMITTAL DATE: February 25, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Parking in the P zone is permitted. A microbrewery is permitted as an accessory use to a food service based on a special exception from the zoning examiner. The following uses are permitted as follows: a. A microbrewery as an accessory use is permitted subject to the following use specific standards: 4.9.4.M.1; 4.9.5.E.6.7, .8. b. Food service is permitted in the C-1 with use specific standards 4.9.4.M.1 and 4.9.13.O. c. Alcoholic beverage service as an accessory use to a food service use is permitted with adherence to 4.9.4.V.1, 3, & 5-9, 4.9.4.C.3 and 4.9.13.O. d. General Merchandise Sales is permitted with 4.9.9.B.3 and 4.9.13.O use specific standards 3. Parking appears to be correct on the supplemental documentation. More information is required to determine parking for the buildings without assigned uses. 4. Bike Parking appears correct and cannot be fully determined without assigned uses. 5. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along 14th street is required. 6. The expansion of the development is greater than 25%. Full code compliance is required. 7. ADA Parking is required. Please show accessible spaces upon submittal of the Development Package. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
| 02/24/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Maximize water harvesting 2. Show pedestrian circulation paths to all frontage roads. 3. Show waste stream calculations and any required trash enclosures. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 02/25/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | 1. Currently this property is served by a 3 - 1" Services connected to the existing 6" CA water main located in 14th St. 2. Additional information about the fire flow, the number, size and type of water meters needed for this development will need to be supplied to Tucson Water, to determine if modeling needs to be performed to verify the existing public water mains have the capacity necessary to serve the proposed development. This can be done via your interactions with the Tucson Water New Services Section. 3. Please contact New Services at TW_Common@tucsonaz.gov (or New Services desk at 520-791-5164) in the Tucson Water New Services Section to discuss options for water service needs. Any questions, comments or concerns about this project may be directed to: Fabien Elenes, Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 Fabien.Elenes@tucsonaz.gov |