Plan Number: T21PRE0024
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T21PRE0024
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2021 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
02/16/2021 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Standard requirements will apply for the development package.

Improvements to Voyager road and Pantano will require a private improvement agreement.

Storm drain crossings for improvements on pantano will be required.

Zelin Canchola
Transportation and Mobility Engieering.
02/16/2021 LOREN MAKUS ENGINEERING REVIEW Completed T21PRE0024
1. Site is within the Airport Wash watershed which is a balanced basin. Balanced basin detention is required.
2. The North Fork of Airport Wash is an ERZ watercourse. Disturbance within the regulatory floodplain must meet ERZ standards.
3. Sidewalk must be separated from back of wedge curb by 2 feet.
Loren Makus, EIT
Loren.makus@tucsonaz.gov
02/18/2021 MROSS2 COT NON-DSD FIRE Completed Fire hydrants required within 400' of all structures.
Cul-de-sacs have a diameter of at least 96'.
The emergency access next to lot 11, needs to be paved, capable of supporting 75,000 lb vehicles.

Michael Ross
Michael.Ross2@tucsonaz.gov
520-837-7082
02/18/2021 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 02/18/21

Tucson Water does not serve this property. For any water questions please contact VOYAGER WATER COMPANY.

Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210, (520) 837-2202
Fabien.Elenes@tucsonaz.gov
02/18/2021 NMARTEL1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Nicholas Martell; Planner
PROJECT: Thursday Pre-submittal meeting - T21PRE0024
Parcel: 14125005B
Zoning: RX-1 to MH-2 (C9-19-17)
Existing Use: Vacant
Proposed Use: Mobile Home Park

TRANSMITTAL DATE: February 17, 2021

COMMENTS:

1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Manufactured Housing and Mobile Home Park are Permitted uses in the MH-2 zone. The use is listed on the plan as Manufactured Home Park. The use is Mobile Home Park. There are no use specific standards.
3. Mobile Home Park density standards allow 15 units per acre. The proposed development is 64.01 acres and 307 lots proposed.
4. Mobile Home Park lot coverage Maximum is 75%
5. Two parking spaces per dwelling unit plus visitor parking required at a ratio of .25 space per unit per UDC 7.4.4-1
6. Minimum lot size standards, as shown, meet the dimensional standards for the MH-2 zone. Ensure all dimensional standards from UDC Table 6.3-2.A will be met.
7. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met.

8. Parking and setbacks for the amenity building appear to be sufficient, but more information about the use of the amenity building is needed to determine zoning standards.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.