Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T21PRE0018
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2021 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 02/08/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | None |
| 02/09/2021 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | Standard requirments will apply. Curb and sidewalk connecting to western existing sidewalk is required. |
| 02/10/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show a continuous pedestrian circulation path for the development as per TSM 7-01.3.3 2. Show that new drainage won't adversely impact neighboring parcels or the areas on the parcel that are included in the critical basin. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 02/11/2021 | ALEXANDRA HINES | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Alexandra Hines, AICP; Lead Planner PROJECT: Thursday Pre-submittal meeting – T21PRE0018 Address: 721 and 651 W ROGER RD Parcel(s): 10605011C and 10605010A Zoning: I-1 Existing Use: Vacant Proposed Use: Animal Service TRANSMITTAL DATE: COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Comply with Use Specific Standards for Animal Service Land Use. 3. Comply with Setbacks. Roger is MS&R and proposed width is 100ft. 4. Submit Lot Combo form to County and provide submittal verification in Development package submittal. 5. What is to happen with the land use/lot/structure to the west? Shared infrastructure and amenities? 6. Showcase parking calculation. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at alexandra.hines@tucsonaz.gov. |
| 02/15/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T21PRE0018 - 635 W ROGER RD - Site Humane Society 1. There is an existing 6" PVC water main (PN 024-2001) in the existing 15' public utility easements on the west and south sides of APN 10605011C. Large trees should not be planted in this easement as shown on the conceptual plan. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210, (520) 837-2106 |