Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: T21PI00015
Parcel: Unknown

Address:
7720 S WILMOT RD

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T21PI00015
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2022 GARY WITTWER DOT LANDSCAPE REVIEW Needs Review Comments:
1. Please add an approved seed mix to the plan that will cover all areas disturbed by construction activities and not covered with hardscape. Seed mixes should correspond to the watershed. Consult Riparian Habitat Mitigation Guide for plants in this watershed.
2. Please install a 6" Sch 40 PVC sleeve at a 2.5 foot depth under the road at the Craycroft intersection that extend 2" beyond the driveways on each side within the ROW. Plug ends to prevent backfill dirt from entering pipe.
05/16/2022 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Completed
05/16/2022 ZELIN CANCHOLA DOT TRAFFIC REVIEW Needs Review - Sheet 2: Why is design speed 45 mph (10 mph over posted speed) instead of 40 mph?
- Sheet 3: I recommend that the typical section is revised to 11 foot travel lanes and 7 foot buffered bike lanes (5+2) (WS4 stripe offset 2' from WS6 travel way edge stripe). Same comment made on Blackhawk PIA where this road ties in
- Sheet 8: From Sta 14+61 on, the plan shows a broken yellow centerline, which would indicated motorists can make passing movements on this 35 mph roadway that includes horizontal curves. Recommend that the YDS4 striping be used the length of the project to prohibit passing movements and encourage motorist traveling speeds to stay low

Thank you,
Greg
05/16/2022 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
05/16/2022 JIM FEMLING DOT STREET MAINTENANCE REVIEW Needs Review
05/16/2022 ERNIE ENCINAS DOT_ELEC REVIEW Needs Review
05/16/2022 RICHARD LEIGH DOT ENGINEERING REVIEW Needs Review
05/16/2022 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed
05/16/2022 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
05/16/2022 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review